AOPOS AS290 /AS260 Cordless Barcode Scanner User Manual Version: AS290/AS260_UM_EN_V1.2.
Notice Make sure you carefully read the following information to ensure that your barcode scanner is able to perform at the level for which it is designed. 1. All software, including firmware, furnished to the user is on a licensed basis. 2. The right is reserved to make changes to any software or product to improve reliability, function, or design. 3. The material in this manual is subject to change without notice. 4.
a higher location, generally more than 1 meter above the ground. location the better.
Safety precautions – Danger! Be sure to read the following safety precautions carefully before trying to use the barcode scanner for the first time. Keep this manual in handy place for future reference. Danger! This symbol indicates information that, if ignored or applied incorrectly, creates the danger of death or serious personal injury. Lithium-ion battery z Never allow the battery to become wet. Water can create the danger of battery heat emission, explosion, and fire.
Safety precautions – Warning! Warning! This symbol indicates information that, if ignored or applied incorrectly, can create the possibility of death or serious personal injury. Disassembly and modification Never try to disassemble or modify the unit in any way. High voltage inside creates the danger of electrical shock. Interior parts and components Never touch interior high-voltage parts or components. Doing so creates the danger of electrical shock.
Cradle with RS-232 cable and adaptor z Power the cradle only with a power outlet whose voltage matches that marked on the adaptor specified in this manual. z Avoid conditions that can cause damage or breaks in the power cord. Do not place heavy objects on the power cord. Keep it away from sources of heat. Any of these conditions can damage the power cord, creating the danger of fire and electrical shock. z Never modify, sharply bend, twist, or pull on the power cord.
Safety precautions – Caution! Caution! This symbol indicates information that, if ignored or applied incorrectly, can create the possibility of personal injury or material damage. Foreign objects Take care to ensure that metal or combustible objects are not inserted into the openings of the unit. Such objects create the danger of fire and electrical shock. Location z Do not locate the unit on a surface that is unstable or uneven.
insulation of the power cord and create the danger of fire and electrical shock. z Never pull on the power cord when unplugging it. Doing so can damage the cord and create the danger of personal injury, fire and electrical shock. Always hold onto the pug when unplugging it from the wall outlet. z Never touch the plug while your hands are wet. Doing so can create the danger of electrical shock. z Be sure to unplug the power cord from the wall outlet before moving the Basic Unit.
Contents Notice......................................................................................................................................................i Safety precautions – Danger!............................................................................................................iii Safety precautions – Warning! ..........................................................................................................iv Safety precautions – Caution! ....................................
Matrix 2 of 5 ........................................................................................................................................ 44 Codabar............................................................................................................................................... 45 Code 128............................................................................................................................................. 46 Code 93 ...........................................
Technical specifications Handheld unit Dimensions Length × Width × Depth: 17.0 × 7.0 × 8.3 cm Weight 201 g Color Gray Battery 1400 mAh Lithium-ion battery Charge time Fully charged (>80%) in 3.
surroundings significantly affect the communication distance in practice. The distance drops quickly in the rainy, high-humidity, or heavy haze day; radio interference also shortens the communication distance. Cradle Input voltage 5 VDC ± 0.25V Cable Straight 2.0m (PS2) / Straight 1.5m (USB) / Straight 2.0m (RS-232 ) Dimensions Length × Width × Depth: 21.3 × 9.7 × 7.
Cable connector pin-outs descriptions for cradle Cable connector interface pin-outs The pin-outs descriptions in Table 1 apply to the cable connector on the cradle and are for reference only. Table 1-1 Cable connector pin-outs descriptions Pin RS232 Keyboard (PS2) 1 Power (+5V) Power (+5V) 2 +3.
Default setting for each barcode Code type Read enable Check digit verification Check digit transmission Min.
Decode zone High-density series Long-range series 5
Dimensions 6
Parts of the scanner Handheld unit ① Exit window ② Trigger ③ Red LED (Charging indicator) ④ Communication/Charge socket ⑤ Power button ⑥ Sound hole ⑦ Red LED (Not successful transmission); Blue LED (Power); Green LED (Setting) Cradle ① B button (Reserved); S button (Upgrade / Reset); P button (USB Emulate) ② Red LED (Initiation failure); Blue LED (Power); Green LED (Data in/Radio frequency hopping indicator) ③ Antenna 7
Power on, power off handheld unit and charge battery Power on handheld unit: Press the power button (see Parts of the scanner) for two seconds. Power off handheld unit: Press the power button (see Parts of the scanner) for two seconds. Charge battery: 1. Please charge the battery before the first time of use. The charge indicator (red LED) on the handheld unit is turned on when the charging is in process. When the charging process completes, the red LED is turned off. 2.
Installation of cradle Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper connections. Go through all steps again. With PS2 cable 1. Plug one end of the PS2 cable to the cradle, one end to PS2 port on PC, and one end to the keyboard. 2. Plug the output of the AC/DC adaptor into the power terminal of on the cradle. Plug the AC/DC adaptor provided by the manufacturer into an electrical outlet. With USB cable 1.
With RS-232 cable 1. Connect the DB9 serial communication cable with the cradle and the COM port of the computer. 2. Plug the output of the AC/DC adaptor into the power terminal of on the cradle. adaptor provided by the manufacturer into an electrical outlet.
Programming instruction The steps of programming are: 1. Scan the SETUP bar code on the parameter setting part. 2. Enter the option mode by scanning the Option bar code. 3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back foldout page. 4. Scan the END bar code, listed on the lower right hand corner of each parameter setting part. 5. Notes that only one parameter can be setup at each time. 6.
Description of point coordination and distributed coordination wireless network Notes: 1. In this section, “cluster” denotes an association of a cradle and a number of handheld units. 2. In this section, “RF” is the abbreviation for “radio frequency”. The scanner offers two kinds of wireless network topology: point coordination and distributed coordination. Point coordination topology: This network topology employs TDM/FDM integrated technique.
Cluster 1 Cluster 2 2. Sketch map of distributed coordination operating mode This series of cordless barcode scanner is working at 430MHz ~432MHz, 433.05MHz~434.79MHz and is covered by a patent of wireless communication method named LR-433-WPAN wireless communication protocol.
Point coordination wireless communication setting 1. Point coordination wireless communication setting for handheld unit Wireless network topology for handheld unit: There are two kinds of wireless network topology that can be employed: point coordination and distributed coordination. Handheld unit RF channel No.: The scanner offers 16 different radio frequency channels for the data transmission between handheld unit and cradle. The number of channel can be increased.
Low battery indicator: If it is enabled, while the power is low, the power LED on the handheld unit flashes 5 times, and the beeper emits 5 beepers for every 10 minutes or 200 scans. In this battery low status, the power LED flashes 2 times by pulling the scanner trigger. Enter sleeping mode interval: If it is enabled, the handheld unit will enter sleeping mode while no operation beyond the time interval defined; the handheld unit will return to normal mode by pulling the scanner trigger.
3)Operations to be performed by the base unit / cradle after receiving the command data packet sent from PC. Command packet Operations of base unit / cradle LED indication VALID Send VALID command packet to the handheld unit. Red LED flashes once, green LED on. INVALID Send INVALID command packet to the handheld unit. Red LED flashes once, green LED off. LOCK Send LOCK command packet to the handheld unit, and then wait for the UNLOCK command packet to be sent from PC.
SETUP Option barcode Option Wireless network topology for handheld unit Handheld unit RF channel No. Alpha.
Note: The settings indicated with (※) are valid only when the cradle is in upgrade ready mode. Cradle entering upgrade ready mode Keep pressing the S button on the cradle, until the blue LED is flashing. Then three LEDs will all be turned ON, this indicates the cradle being upgrade ready mode.
2. Point coordination wireless communication setting for cradle Wireless network topology for cradle: There are two kinds of wireless network topology that can be employed: point coordination and distributed coordination. Cradle RF channel No.: The scanner offers 16 different radio frequency channels for the data transmission between handheld unit and cradle. Bind the first handheld unit ID: This setting is used to bind the first handheld unit ID.
SETUP Option barcode Option Wireless network topology for cradle※ Cradle RF channel No.※ Point coordination 00* Distributed coordination 01 02-16 Bind the first handheld unit ID※ 01-16 Recruit a next handheld unit ID※ Radio power level for cradle Frequency hopping Alpha.
Distributed coordination wireless communication setting 1. Cluster establishment example 1.1 Establish the wireless link between the cradle and the first handheld unit. Step 1.0 Please refer to chapter “return default parameters & version chapter” to check the current wireless network topology. If it is point coordination network topology,please scan the optional barcode 0700 and 0800 to change the network topology. Step 2.0 Scans the following barcode to return to default parameters.
1.2 Establish the wireless link between successive handheld units and the same cradle. Step 5.0 Please refer to instruction in previous section to pair the cradle with the first handheld unit. Step 6.0 Repeat steps 3.0~3.3 to set radio address of the second handheld unit. Step 7.0 Scan JOIN barcode to pair the second handheld unit with the cradle. )The blue LED on the handheld unit will blink to indicate that the handheld unit is ready to be positioned onto the cradle. Step 7.
2. Distributed coordination wireless communication setting for handheld unit Wireless network topology for handheld unit: There are two kinds of wireless network topology that can be employed: point coordination and distributed coordination. Handheld unit RF channel No.: The scanner offers 16 different radio frequency channels for the data transmission between handheld unit and cradle. The number of channel can be increased.
SETUP Option barcode Options Wireless network topology for handheld unit Handheld unit RF channel No.
3. Distributed coordination wireless communication setting for cradle Wireless network topology for cradle: There are two kinds of wireless network topology that can be employed: point coordination and distributed coordination. Cradle RF channel No.: The scanner offers 16 different radio frequency channels for the data transmission between handheld unit and cradle. Radio power level for cradle: By selecting, you can change the radio frequency power level for cradle.
Scanning When the scanner is scanning, ensure the scan line crosses every bar and space of the symbol.
Keyboard wedge for Cradle Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Keyboard layout: The scanner supports different national keyboard layouts. Clock period: According to the PS2 protocol, the clock is provided by the device, e.g. keyboard or scanner, with the period between 60us to 100us.
SETUP Option bar code Keyboard type Keyboard layout Clock period Delay-after-compound-key Numeric key Power-on simulation Inter-character delay Inter-byte delay Caps Lock reversion Caps Lock override Option Alpha.
SETUP Option bar code Option Alpha.
RS-232 interface for Cradle Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout duration, the scanner will issue an error indication.
SETUP Option bar code Flow control Inter-character delay Option Alpha.
USB interface for Cradle USB device type: When the cradle is connected to a PC with a USB cable, it will be identified as a HID keyboard. Keyboard layout: Refer to Keyboard layout of Keyboard wedge for Cradle. Host comm. port speed: By selecting, the user can change the output speed of the scanner to match the speed of the host USB communication port. speed.
Handheld scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning.
Decoder optimization: If it is enabled, the scanner will optimize the decoder with error correction. function is not effective for all types of barcodes. SETUP Option bar code Scanning mode Standby duration Option Alpha. entry Good-read off 00 Momentary 01* Alternate 02 Continue 03 Timeout off 04 01-99 (second) 01-99 04* Same barcode delay time 00-FF16 (50ms) 00-FF16 08* Double confirm Global max. code length 00-09 00-09 (00: no ) 00* 04-99 04-99 99* Global min.
Visual and audio indication for Handheld unit Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep to indicate a good barcode reading, and its beep tone duration is adjustable.
UPC-A Read: Format Leading zero Data digits (11 digits) Check digit Check digit verification: The check digit is optional. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Code ID is a one-or-two-character string used to represent the symbol upon a succeeding reading. be enabled. If you want application to transmit Code ID, you must set Code ID transmission to Refer to the chapter of String transmission.
UPC-E Read: Format Leading zero Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
EAN-13 Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
EAN-8 Read: Format Data digits (7 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
Code 39 Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆ Check digit verification: The check digit is optional and made as the sum module 43 of the numerical value of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Each symbology has own max./min. code length. If both setting of max./min. code length are “00”s, the setting of global max./min. code length is effective.
SETUP Option bar code Option Read Check digit verification Check digit transmission Max. code length Alpha. entry Disable 00 Enable 01* Disable 00* Enable 01 Disable 00* Enable 01 00-99 00-99 00* Min.
Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits. There are two optional check digit algorithms: the specified Uniform Symbology Specification (USS) and the Optical Product Code Council (OPCC). Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39.
Industrial 2 of 5 Read: Format Data digits (variable) Check digit (optional) Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. SETUP Option bar code Option Read Max. code length Alpha. entry Disable 00* Enable 01 00-99 00-99 00* Min.
Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
Codabar Read: Format Start Data digits (variable) Check digit (optional) End Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
Code 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
Code 93 Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional) Check digit verification: The check digit is presented as the sum module 11 of all data digits. Check digit transmission: By setting Enable, check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A.
MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey has one or two optional check digits. methods of verifying check digits, i.e. Mod10, Mod10/10 and Mod 11/10. There are three The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits.
UK/Plessey Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The UK/Plessey has one or two optional check digits. check digit 2 will be calculated as the sum module 10 or 11 of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max. /Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Truncate leading zeros: Refer to Truncate leading zeros of Code 128.
China Post Read: Format 11 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. SETUP Option bar code Option Read Alpha.
GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater than or equal to 33 modules. Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.
GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Conversion: Refer to Conversion of GS1 DataBar (GS1 DataBar Truncated). SETUP Option bar code Option Read Code ID setting Insert group selection Alpha.
GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Conversion: UCC/EAN 128- Refer to Code ID transmission of String transmission, ]Cm will be identified as AIM ID. SETUP Option bar code Read Max. code length Option Alpha. entry Disable 00 Enable 01* 00-99 00-99 00* Min.
PDF417 This decoder is only applied with a specified firmware. The symbol size in the standard of PDF417 says, number of rows: 3 to 90, and number of columns: 1 to 30. This scanner can only decode PDF417 at rows from 3 to 40 and columns from 1 to 20. The error correction level for a PDF417 symbol is from 0 to 8. This scanner can only support the levels from 0 to 6. Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A.
MicroPDF417 This decoder is only applied with a specified firmware. Read: Format Data characters (variable) Max. /Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. SETUP Option bar code Option Read Max. code length Alpha. entry Disable 00* Enable 01 00-99 00-99 00* Min.
China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the symbol of 0 to 9, 0 and 2, 4 and 9, 5 and 8, 6 and 7, have the symmetrical pattern; the pattern of 1 and 3 is symmetrical. Read: Format 10 Data digits Max./Min. code length: Refer to Max./Min. code length of Code 39. Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits.
SETUP Option bar code Read Max. code length Option Alpha. entry Disable 00 Enable 01* 00-99 00-99 10* Min.
G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Suffix string setting: The key is represented in different ASCII when it is applied by different OS. For a Windows/DOS OS, is represented as (0x0D 0x0A); for an APPLE MAC OS, is represented as (0x0D); for a Linux/Unix OS, is represented as (0x0A).
FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substituted with a defined string. Truncate leading G5 string setting: By setting, a defined leading character or string can be truncated. Also a single character can be un-defined. Repeat of a G5 character setting: While G5 is set as a single defined/un-defined character, G5 can also be set to be repeated.
SETUP Option bar code Prefix string setting Suffix string setting Preamble string setting Postamble string setting Insert G1 string setting Insert G2 string setting Insert G3 string setting Insert G4 string setting FN1 substitution string setting Truncate leading G5 string setting Repeat of a G5 character setting Truncate ending G6 string setting Repeat of a G6 character setting Single character C1 replacement Single character C2 replacement Option Alpha.
G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Insert G1/G2/G3/G4 string position: The scanner offers 4 positions to insert strings among the symbol. In case of the insertion position is greater than the length of the symbol, the insertion of string is not effective. Code ID position: It is allowed to select different positions of code ID placement.
String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Preamble transmission: By setting Enable, preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, postamble will be appended after the data is transmitted.
SETUP Option bar code Prefix transmission Suffix transmission Code name transmission Preamble transmission Postamble transmission Code ID transmission Code length transmission Case conversion FN1 substitution transmission All-non-printable-character string transmission with string setting Option Alpha.
Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Read disable) Matrix 2 of 5 Code 93 UCC/EAN 128 Code 11 (Default setting: Read disable) 66
Test Chart (Continued) MSI/Plessey (Default setting: Read disable) UK/Plessey ISBN/ISSN China Post GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Limited GS1 DataBar Expanded PDF417 01Az+-= MicroPDF417 23+-mdo 67
Troubleshooting Problem Possible causes Possible solutions Nothing happens when you No power to the Check the system power. Ensure the power follow the operating scanner. supply is connected. instructions, or the scanner Incorrect cables. Use the original cables. displays erratic behavior. Connections are Check for loose cable connections. loose. Laser comes on, but the Bar code symbol is Check the symbol to make sure it is not scanner does not decode. unreadable. defaced.
Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. 1. Do not allow any abrasive material to touch the window. 2. Remove any dirt particles with a damp cloth. 3. Wipe the window using a tissue moistened with water. 4. Do not spray water or other cleaning liquids directly into the window. 5. Use a piece of soft and dry cloth when cleaning the scanner.
ASCII table for keyboard wedge H L 0 Null 1 Up 2 0 for RS-232 1 0 1 NUL DLE F1 SOH DC1 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EOT DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN F7 BEL ETB 7 8 Bs F8 BS CAN 9 Tab F9 HT EM F10 LF SUB A B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl+ SO RS F Delete Alt+ SI US Notes: The 2nd and the 3rd columns above are used for keyboard wedge only.
Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the method of printing following barcode is different. 2. If using CODESOFT software, firstly read the information through “Help→Index→Code128→Special input syntax”. Also refer to ASCII table. For example, if we wish to make “F1” barcode, select “code128”, then select “CODE A” type, and input “{DOC1}” as data.
Return default parameters All parameters of handheld unit return to default setting WARNING: If you wish to return all parameters of the handheld unit, including radio communication setting, to default setting, please scan the barcode above. All parameters of cradle return to default setting※ WARNING: If you wish to return all parameters of the cradle, including radio communication setting, to default setting, please scan the barcode above.
Display firmware version & radio communication setting Cradle firmware version display If you wish to display the firmware version of the cradle, please scan the barcode above. Handheld unit firmware version display If you wish to display the firmware version of the handheld unit, please scan the barcode above. Cradle radio communication setting display※ If you wish to display the radio communication setting of the cradle, please scan the barcode above.
Quick setting to point or distributed coordination wireless network The steps of setting are: 1. Both the handheld unit and the cradle are in normal working mode. Normally it means that only the blue LED on the handheld unit and only the blue LED on the cradle are ON as shown below. The scanner offers two kinds of wireless network topology: point coordination and distributed coordination.
Configuration alphanumeric entry barcode 75