User manual
49 
MSI/Plessey 
Read: 
Format 
Data digits (variable)  Check digit 1 (optional) Check digit 2 (optional) 
Check  digit  verification:  The  MSI/Plessey has  one  or  two optional  check  digits.      There are  three 
methods of verifying check digits, i.e. Mod10, Mod10/10 and Mod 11/10.    The check digit 1 and check 
digit 2 will be calculated as the sum module 10 or 11 of the data digits. 
Check digit transmission: By setting Enable, check digit 1 and check digit 2 will be transmitted upon your 
selected check digit verification method. 
Max./Min. code length: Refer to Max./Min. code length of Code 39. 
Code ID setting: Refer to Code ID setting of UPC-A. 
Insertion group selection: Refer to Insertion group selection of UPC-A. 
    SETUP 
Option bar code  Option  Alpha. entry 
Read 
Disable 
Enable 
00* 
01 
Check digit verification 
Disable 
1 digit (mod 10) 
Reserved 
Reserved 
00* 
01 
02 
03 
Check digit transmission 
Disable 
Enable 
00* 
01 
Max. code length 
00-99 
00-99 
00* 
Min. code length 
00-99 
00-99 
00* 
Code ID setting 
00-FF
16
(ASCII) 
00-FF
16
<O>* 
Insert group selection 
00-66 
00-66 
00* 
Reserved 
 END 