Specifications

137
Access the COPY EXT-MEM menu using the key sequence .
Select the “LOAD” option, to toggle between load and save. Next select the EM8200
bank you wish to load using the keys or main dial (0, 1, 2 or 3). the key to move the
cursor to the left of the “ALL-DATA” legend, use the keys to select “SRCH-BANK”. the
key to move the cursor to the right of the legend “SRCH-BANK “ to enable selection of the desired
search bank to load. Use the main dial, keys or keypad to select the desired search bank.
to start the search data load. The legend “EXT-MEM LOADING !!” will be displayed
with the exclamation marks flashing to indicate that loading is in progress. The search load process will
take a couple of seconds to complete. Once the load is complete, the LCD will revert to its previous
display (VFO, scan or search etc).
18-7-7 EM8200 internally stored band scope save and load
It is possible to save the internally stored band scope to the EM8200 external memory locations 0, 1,
2, 3 or 4 using the “COPY EXT-MEM” menu. If a band scope trace is currently ‘actively’ displayed on
the LCD while in BAND SCOPE mode, it may also be saved to external memory.
Save B-SCOPE
To save the internally stored band scope to external memory,
access the COPY EXT-MEM menu using the key sequence
.
Select the “SAVE” option, to toggle between
load and save. Next select the EM8200 bank you wish to save
using the keys or main dial (0, 1, 2 or 3).
the key to move the cursor to the left of the
ALL-DATA” legend, use the keys to select “B-SCOPE”.
to start the band scope data save. The legend
EXT-MEM SAVING !!” will be briefly displayed, the save process
will only take a second to complete. Once the save is complete,
the LCD will revert to its previous display (VFO, scan or search
etc).
Load B-SCOPE (for future display)
It is presumed that you have already saved band scope data to one of the four EM8200 memory
locations. Make sure that global write protect is not set or the data load will be unsuccessful and no
data will be loaded. It is also possible to load a band scope trace directly into the band scope display for
immediate viewing, this is explained at the end of this section.
If you wish to retain any currently displayed band scope, save it to one of the four locations in the
external EM8200.
Access the COPY EXT-MEM menu using the key sequence .
Select the “LOAD” option, to toggle between load and save. Next select the EM8200
bank you wish to save using the keys or main dial (0, 1, 2 or 3).
Section 18-7-6, 18-7-7