User`s manual

AOR
HAWK 5000 for
Windows
TM
User’s Manual - Page 9
The pin configuration of the
SDU5000
to PC cable is as follows:
SDU5000
9-way PC 25-way
2 (TX) 3 (RX)
3 (RX) 2 (TX)
8 (RTS) 5 (CTS)
7 (CTS) 4 (RTS)
5 (signal ground) 1, 7 (signal ground)
You must include the hardware flow control connections for correct
operation.
If you are using an Icom radio with a CT-17 interface, you will can use the
Icom supplied RS-232 cable (part no. OPC-159) to connect the CT-17 to the
PC and one of the Icom supplied cables with 3.5mm plugs on them to connect
your Icom radio to the CT-17 (consult the installation instructions that come
with the CT-17 unit for further details). You must also connect the
SDU5000
to
the CT-17 using the AOR supplied cable from the RX CONTROL socket to the
25-way RS-232C connector on the CT-17 unit.
Starting the program
To launch
AOR
Hawk 5000 for
Windows
TM
:
If you are using
Microsoft
®
Windows
TM
3.x, select the
AOR
Hawk 5000
program group and double-click on the icon. If you are using
Windows
®
95,
select the
AOR
Hawk 5000 shortcut from the Programs menu option of task
bar and the application’s icon.