REPLACEMENT AIR NOZZLES AOYUE ® INT 2702A+ Lead-Free Repairing System INSTRUCTION MANUAL Thank you for purchasing Aoyue Int2702A+ Repairing System. It is important to read the manual before using the equipment. Please keep manual in accessible place for future reference. (*) Sold Separately Manufacturer: AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY Jishui Industrial Zone, Nantou, Zhongshan City, Guangdong Province, P.R.China http://www.aoyue.
This manual is designed to familiarize and instruct the operator with the proper usage and maintenance of the equipment. The “Care and Safety Precautions” section explains the hazards of using any type of soldering or reworking device. Please read carefully and observe the guidelines in order to maximize usage and minimize the risk of injury or accidents .
BASIC TROUBLESHOOTING GUIDE PROBLEM 7: AIR PRESSURE LEVEL IS SIGNIFICANTLY LOW NO MATTER HOW HIGH THE AIRFLOW LEVEL IS CALIBRATED Case 1: Check the mains voltage (AC power source).
PACCKAGE INCLUSIONS BASIC TROUBLESHOOTING GUIDE PROBLEM 1: THE UNIT HAS NO POWER 939 Vacuum Suction Pen 2702 Main Station G001 IC Popper 1. Check if the unit is switched ON. 2. Check the fuse. Replace with the same type if fuse is blown. 3. Check the power cord and make sure there are no disconnections. 4. Verify that the unit is properly connected to the power source.
CARE and MAINTENANCE FUNCTION and FEATURES Changing nozzle: ● Unscrew the securing lock and pull out the heater external housing together with the securing lock, Nozzle can now be changed. Re-secure nozzle by tighten the securing lock on its receptacle. Changing Filter pad and Filter Spring: ● Unlock the filter dock by toggling the filter dock locking mechanism.
CARE and MAINTENANCE SAFETY PRECAUTIONS CAUTION: Improper usage can cause serious injury to personnel and/or damage to equipment. For your own safety, please observe the ff. precautions. ● Check each component after opening the package to make sure everything is in good condition. If there are any suspected damage, 4. Inside the pipe, the quartz glass and heat insulation are installed. Loosen the cable and take out the heating element. 5. Insert new heating element and reconnect the terminal.
CARE and MAINTENANCE Spare Parts Guide Part No. 10094 30106S S009 20962 B012 C005 3072D B1003 ASSEMBLY and PREPARATIONS A.
CONTROL PANEL GUIDE DIGITAL CALIBRATION NOTES: 1 2 13 3 12 10 4 14 11 ● The calibrated data is saved into the memory an shall remain effective until it is recalibrated again or new data is entered. ● If the maximum of 70 degrees has already been added or subtracted pressing the air pressure down button would not exit from calibration mode. Instead turning off the soldering iron 9 function switch would exit from the calibration mode.
DIGITAL CALIBRATION 6. OPERATING GUIDELINES Adjust the temperature compensation using the UP and DOWN buttons of the Soldering iron adjustment buttons. 7. A zero “0” on the first digit signifies addition to the current temperature and a minus “-” on the first digit will subtract the displayed value from the current settings. 8. Confirm the change by pressing the air pressure down IMPORTANT REMINDERS: 1.
OPERATING GUIDELINES 4. Adjust the air flow level using the AIR PRESSURE ADJUSTMENT BUTTONS (“3” from the control panel). DIGITAL CALIBRATION 3. Release the two buttons after the change in display. 4. Use the same two buttons to adjust the countdown time. 5. Adjust the hot air gun air temperature using the HOT AIR GUN “t001” means solder iron will go to sleep in 1 minute. Timer is TEMPERATURE ADJUSTMENT BUTTONS (“2” from the control panel).
AUTO SLEEP FUNCTIONS OPERATING GUIDELINES 1. While the hot air gun is on stand-by mode (“0FF” is displayed on the panels “13” and “12”), hold both UP and DOWN buttons of the HOT AIR GUN TEMPERATURE adjustment buttons. 2. Wait until “t005” is displayed on the Hot Air Gun Temperature display panel, “13”. NOTES: 1. Hot Air Gun Temperature is adjustable between 100° and 480°C with an increment of 2° on each step. 2.
OPERATING GUIDELINES 3. Connect the vacuum tube to the Smoke Absorber Terminal or AUTO SLEEP FUNCTIONS ● Vacuum Cap (“6” from the control panel). If smoke absorber function is to be used. 4. Activate the “SOLDER IRON” Activation switch (“9” from control panel). This will automatically start to increase the temperature of the desoldering gun to 350°C (default). 6. Adjust the desoldering gun temp. using the SOLDER/DESOLDER TEMPERATURE ADJUSTMENT buttons (“4” from the control panel). 7.