aoyue ® INT 2703A+ Advanced LeadFree Repairing System INSTRUCTION MANUAL Thank you for purchasing Aoyue Int2703A+ Repairing System. It is important to read the manual before using the equipment. Please keep manual in accessible place for future reference. Manufacturer: AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY Jishui Industrial Zone, Nantou, Zhongshan City, Guangdong Province, P.R.China http://www.aoyue.
This manual is designed to familiarize and instruct the operator with the proper usage and maintenance of the equipment. The “Care and Safety Precautions” section explains the hazards of using any type of soldering or reworking device. Please read carefully and observe the guidelines in order to maximize usage and minimize the risk of injury or accidents .
REPLACEMENT TIPS PRODUCT DESCRIPTION The Aoyue INT2703A+ Advanced LeadFree Repairing System is a reworking equipment that combines the functionality of Hot Air Gun, Soldering Iron, Smoke Absorber, and Desoldering Gun in one package. The dual port system of the Int2703A+ allows simultaneous use of the desoldering gun and soldering iron. The nozzle is specially designed with air spreader technology to disperse heat and air evenly greatly enhancing the heat output for more effective reflows.
SPECIFICATION BASIC TROUBLESHOOTING GUIDE MAIN STATION Power Input : Station Dimensions: available in 110V / 220V 188(w) x 126(h) x 250(d) mm Weight: 5.
BASIC TROUBLESHOOTING GUIDE PACCKAGE INCLUSIONS PROBLEM 6: SOLDERING IRON TEMPERATURE DISPLAY PANEL SHOWS “PLUG” CHARACTERS Case 1: The system shows “PLUG” from the soldering iron temperature display panel . 939 Vacuum Suction Pen 2703A+ Main 03 27 A+ SOLUTION 1:Check if the soldering iron connection assembly is properly connected and secured to the receptacle on the control panel. SOLUTION 2:Make sure the soldering iron tip is properly inserted and secured inside the handle.
FUNCTION and FEATURES ● Microprocessorcontrolled ESD safe equipment. ● 3in1 repairing system combining Hot Air Gun, Soldering Iron, and ● Desoldering Gun in one sophisticated package. Advance technology air spreader nozzle ● Digital control and display of hot air temperature, soldering iron temperature, desoldering gun temperature and air pressure with ● touch type panel controls for precision and ease of use.
CARE and MAINTENANCE SAFETY PRECAUTIONS Changing nozzle: ● Unscrew the securing lock and pull out the heater external housing together with the securing lock, Nozzle can now be changed. Resecure nozzle by tighten the securing lock on its receptacle. Changing Filter pad and Filter Spring: ● Unlock the filter dock by toggling the filter dock locking mechanism.
ASSEMBLY and PREPARATIONS A. Main Station As soon as the equipment has been removed from the package, REMOVE THE SCREW located at the center of the bottom of the main unit. This screw holds the pump in place during transportation. WARNING: Failure to remove the screw before using the equipment can cause damage to the system. B. Soldering Iron 1. Install the solder wire to the soldering iron holder as in Figure 1. CARE and MAINTENANCE 4. Inside the pipe, the quartz glass and heat insulation are installed.
CARE and MAINTENANCE CONTROL PANEL GUIDE Spare Parts Guide Part No.
OPERATING GUIDELINES IMPORTANT REMINDERS: 1. Make sure the equipment is placed on a flat stable surface and all the heatgenerating components placed on their respective holders or stands. 2. Ensure all function switches are OFF prior to reworking. 3. Ensure all terminal connections are properly secured. IMPORTANT: Please refer to the CONTROL PANEL GUIDE page for buttons and display panel directory. A. INITIAL PROCEDURES 1.
DIGITAL CALIBRATION OPERATING GUIDELINES I. Utilizing the Desoldering Gun Digital Temperature Calibration 1. Turn on the Desoldering gun function switch. 2. Set to appropriate temperature you want to calibrate. Place the tip of the desoldering gun on an external temperature meter. 3. The readings on the external temperature sensor should be more or less equal to the displayed temperature. 4. If there are large discrepancy in the temperature reading we can recalibrate the temperature setting.
OPERATING GUIDELINES C. AUTOMATE FUNCTION The system is equipped with a 5 stage automated hot air rework profiling system. To access and change the time and temperature settings of the profile follow the guide below: DIGITAL CALIBRATION 1. Ensure that the hot air gun function switch is deactivated. 2. The Hot Air Gun Automate Function Selector (“17” from the control panel) allows us to scroll thru the different stages of the profile.
AUTO SLEEP FUNCTIONS OPERATING GUIDELINES Changing SLEEP Timer (Desoldering Gun) By default, the system’s sleep duration is 0 indicating the sleep timer is disabled. To activate the sleep function follow the procedures. 1. Turn off the Soldering Iron Function switch (“14” from the control panel) .Ensure that the Desoldering Gun Function switch is in the off position(“12” from the control panel) . 2.
OPERATING GUIDELINES D. SOLDERING IRON 1. Connect the Soldering Iron connection assembly to the 6pin receptacle located at the front of the control panel (“9” from the CONTROL PANEL GUIDE). 2. Follow the initial procedures (“A. INITIAL PROCEDURES”). 3. Connect the vacuum tube to the Smoke Absorber Terminal or Vacuum Cap (“7” from the control panel). If smoke absorber function is to be used. 4. Activate the “SOLDER IRON” Activation switch (“14” from control panel).
AUTO SLEEP FUNCTIONS OPERATING GUIDELINES F. AutoSleep Mode (Hot Air Gun) The device has a builtin autosleep mode feature such that if the Hot Air Gun sits on its handle and remained idle after a certain period the prefix of the display for Hot Air Gun air temperature will also change from “C” to “d”) , the device will switch to sleep mode. This mechanism is triggered by a countdown timer.
OPERATING GUIDELINES ● The soldering iron and desoldering gun operating temperature is ● configurable between 200°C and 480°C Because of the difference in the heating element and size of the ● soldering iron tip and desoldering gun, the soldering iron will heat up faster than the desoldering gun. This is normal and does not have any impact on the system’s performance. There will be a slight drop in temperature display once the trigger of the desoldering gun is used.