Operator`s manual

15
9 Menu Functions
AVG - Numeric & Arrow Averaging - HI / MD / LO - Averages
laser beam strikes to improve arrow display performance at long
distances. Algorithm factors in laser RPM and accuracy setting.
MD is default setting and used for most applications.
HI can be used in windy conditions, when the laser beam may
be unstable, or when working at long distances. NOTE: Refer to
the laser's speciî‚¿cations for accuracy and distance information.
LO uses minimum averaging to display laser strikes.
D.R.O. - Digital Read Out - ON / OF - Turns the numeric display
On or Off. Default is ON.
UNIT - Units of Measure - Select centimeters (cm), millimeters
(mm), inches (in), fractional inches (in), or feet (ft). Default is mm.
FRC.R - Fractional Reduction - ON / OF - Applied when
fractional inches are Units of Measure selected.
ON reduces fractions to the least common denominator.
OFF leaves fraction in reducible form.
Default is ON.
ARRW - Arrow Display - DB / PR - Adjusts how the off-grade
arrow and bars are displayed. Default is DB.
DB - Deadband - each bar represents the deadband or accuracy
setting. NOTE: For larger deadbands, all bars may not be
displayed.
PR - Proportional - each bar represents the available vertical
reception range divided by the number of segments.
O.O.B - Out-of-Beam Display - ON / OF - ON displays a
sequence of arrows that indicate when the receiver has moved
beyond the vertical laser reception range. The sequence will
indicate which direction to move to get back in the laser beam.
The display remains on for approximately 25 seconds.
OF turns the display Off. Default is ON.