Extra Information

CONCEPT1 RS232 COMMUNICATION
WWW.APART-AUDIO.COM
INFO@APART-AUDIO.COM
Status Update
VALFB stands for Value Feed Back. When this seng is on, all value changes are sent “autonomously” by Concept
1. This way its easy to keep the status synced. Default, VALFB is on. IPGAIN and SOURCENAME are NOT sent when
they are modied.
INFO can only be used with the GET command. The GET INFO instrucon is replied with the current status of most
variables. It will only work when VALFB is on. IPGAIN and SOURCENAME is not sent aer the GET INFO instrucon
but their status can also be requested with the GET command. Below is an example of a reply aer a GET INFO
instrucon in stereo mode. The <CR> characters at the end of the line are not shown:
PAGING OFF
MULTIZONE OFF
PAGACT ON
AUTOLD ON
SELECT A
MSCLVL OFF
MICLVL OFF
MAXMSCLVL 0
MAXMICLVL 0
EQBASS 0
EQTREB 0
Source Name
With SOURCENAME, its possible to change or read the source name thats shown on the display of the Concept
1. There always has to be a source (A, B, C or D) specied. The source name string itself is case sensive and may
contain space characters. Example:
Instrucon: get sourcename a<CR>
Reply: Source A<CR>
Instrucon: set sourcename a BGM3000<CR>
Reply: Command Executed!<CR>
Instrucon: get sourcename a<CR>
Reply: BGM3000<CR>
Version information
The following aributes will only work with the GET command:
SERIAL will return the serial number, a 4 digit hex number. In case its not programmed, it will return “Not Yet
Implemented!<CR>”.
HWVRSN will return the hardware version number
SWVRSN will return the hardware version number