CONCEPT1(T) Instruction manual
CONCEPT1(T) CONCEPT1(T) Manual Instruction manual 3
Integrated amplifiers Safety Instructions • P lease check the carton box for any kind of damage on reception of the goods. In case of a damaged carton, please contact your dealer before opening the carton. • ! !!! Danger !!!! Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient amount of time.
CONCEPT1(T) Instruction manual • o not connect the inputs / outputs of amplifiers or consoles D to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off. • P ower down & disconnect units from mains voltage before making connections. • o not use the unit near stoves, heat registers, radiators, or D other heat producing devices.
Integrated amplifiers Main features • basic operating modes combined in 1 device: stereo, linked 3 mono and individual mono. • P aging microphone input with 2 zone programmable paging control. • Standalone and/or RS232 controlled operation. • Removable 19 inch rack ears. • Menu driven hidden configuration accessible for installers only. • Lockable front panel controls. • Super simple no nonsense user interface. • Multi functional stylish blue colour dot matrix VFD display.
CONCEPT1(T) Instruction manual • L ow impedance (Concept 1) and 100 volt speaker line outputs (Concept 1T) available. • Integrated limiter circuit. • IR remote control optionally available. • IR control extender optionally available. • x 60 watts freely assignable RMS output power at your 2 disposal.
Integrated amplifiers Front panel and display layout 10 11 9 1 2 4 3 6 7 8 5 1. P ower on/off button: push this button to turn the power on and off 2. Source A selector: push this button to select line source A 3. Source B selector: push this button to select line source B 4. Source C selector: push this button to select line source C 5. Source D selector: push this button to select line source D 6.
CONCEPT1(T) Instruction manual 10. Infrared receiver 11.
Integrated amplifiers Rear panel layout 4 1 2 3 5 7 6 9 8 11 12 13 14 15 16 17 18 10 1. Microphone input: connect your (paging) microphone on this euroblock connector, connect the signal on +, -, the screen on GND. Connect the eventual paging contacts between GND and Z1 (for zone 1) and between GND and/or Z2 (for zone 2). The input gain can be adjusted with knob 2 between line and mic level to avoid distortion. 2. Mic input gain control: mic input gain adjust 3.
CONCEPT1(T) Instruction manual 9. Line D: stereo line RCA connector, a mini jack version of the line D input is available on the front panel. Only use one of the two input’s at the same time. 10. P re-amp out: these RCA connectors offer a line level signal, after the master volume, but before the limiter. For details, please take a look at the block diagram on page 7. 11. Line out: these RCA connectors carry the line level signal after passing the volume control and limiter circuit.
Integrated amplifiers 17. R S232: 9 pin sub D connector for connection of computers or other automated audio system controllers 18. AC input: plug in the supplied mains cable here. Check your mains voltage first ! CONCEPT1T Version Difference on CONCEPT1T 1 2 3 4 1. lo-cut Right channel / zone 2: switch not available 2. R ight channel / zone 2 output on euroblock connector: minimum load impedance: 167 ohms or 60 watts / 100 volts 3. lo-cut Left channel/zone 1: switch not available 4.
CONCEPT1(T) Instruction manual User Operation The table below shows the 3 possible operating modes: stereo, 2 separate mono zones with one linked music volume control and 2 separate mono zones with individual music volume control. You can adjust the volume by turning the large rotary control from -80 dB (lowest) to 0 dB (highest). Volume adjustment is the default parameter assigned to the rotary control. In order to enter the menu, press the select button next to the large rotary control.
Integrated amplifiers
CONCEPT1(T) Instruction manual Expert Operation In order to edit the EXPERT parameters, push select repeatedly until “EXPERT” appears in the display. Then press the ‘SELECT’ and the ‘SOURCE D’ button. A hidden menu structure is now available and gives you the opportunity to edit several parameters, such as operating mode, maximum music level and so on. The table shows the entire menu structure. The menu tree is also printed on top of the Concepct1 unit and should need no further explanation.
Integrated amplifiers Accessories CONCEPT1-RC Infrared remotecontrol unit. MICPAT-2 2-zone paging microphone.
CONCEPT1(T) Instruction manual CONCEPT1T-KIT Kit of 2 pcs 100 volt transformers to change 1 or 2 channels of the CONCEPT1 into 100 volt line outputs.
Integrated amplifiers ERROR conditions Symptom Display Solution No power No display Replace main fuse. The fuse is located inside the unit near the power switch. For qualified personnel only. No power, unit is very hot No display Power off the unit, wait for cool down and power on again. No sound Amp error Switch power off and on again, if error is not solved, check amp fuses on main pcb and replace if necess ary. For qualified personnel only.
CONCEPT1(T) Instruction manual Technical Specifications CONCEPT 1 Dynamics program power, both channels driven, 8 ohm 50 W + 50 W Dynamics program power, both channels driven, 4 ohm 80 W + 80 W Dynamics capacity at 1,7 ohm dips / ch 120 W Note Power output controlled by digital limiter Lo-cut filter 75 Hz / 12 dB / oct Speaker impedance - connection 4 - 16 ohms / ch - euroblock secured screw terminals Digital control RS232 Sub-d9, galvanically isolated IR (ir-remote control optional) Front
Integrated amplifiers Micro balanced input rear panel gain trim -56 / -16 dBV mic - line Micro tone control ; rear panel lo - hi 100 Hz / +3 dB,10 kHz / -6 dB to 100Hz/-9 dB, 10 kHz / +4 dB Pre-out impedance / sensitivity 1 K ohm / 0 dBV Line-out impedance / sensitivity 1 K ohm / +3 dBV General Operation modes Stereo / 2 zones linked / 2 individual zones Micro paging 1 or 2 zone Frequency response (- 0,5 dB) 10Hz - 40 kHz THD < 0,05% IMD < 0,09% Noise a-weighted > 100 dBV Gain 33 d
CONCEPT1(T) Instruction manual Net weight 6.6 kg Gross weight 7.6 kg CONCEPT 1T (100 volt output version) All specs same as above, except: RMS program power, both channels driven, 167 ohms / ch, 60 W / 100 volt + 60 W / 100 volt Net weight 8.2 kg Gross weight 9.
Integrated amplifiers Note
developed by Audioprof nv Industriepark Brechtsebaan 8 bus 1 2900 Schoten - Belgium Company names, product names and trademarks are property of their respective owners. Apart-Audio specifications are subject to change without notice.