PROFESSIONAL POWER AMPLIFIER Safety first! • aution! This professional device needs to be installed by C qualified personnel only. • P lease check the carton box for any kind of damage on reception of the goods. In case of a damaged carton, please contact your dealer before opening the carton. • ! !!! Danger !!!! Exposure to high sound levels may cause a permanent hearing loss.
REVAMP2600 Instruction manual • S et level controls on amplifiers all the way down during powerup to prevent speaker damage if there are high signal levels at the inputs. • o not connect the inputs / outputs of amplifiers or consoles D to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off. • P ower down & disconnect units from mains voltage before making connections.
PROFESSIONAL POWER AMPLIFIER Features • 2 rack units high • Class H amplifier topology • 2 channel amplifier • Dynamic output power: 2x840W @ 4Ω • Sine wave power per channel: 2x600W @ 4Ω(500 msec) • High thermal efficiency • Highest possible damping factor • Analog power supply with toroidal power transformer • Active variable speed cooling fan • Low power consumption • I ntegrated Analog Devices® digital signal processor (DSP) with easy one button operation: simply push the button
REVAMP2600 Instruction manual • Input level attenuators on all inputs • 4-pole Speakon® speaker output connectors • Euroblock speaker output connectors • E xtended speaker and amp protection circuits: DC protect, over current protect, over temperature protect, input overload • I ndividual channel mute buttons and versatile LED status indicators • T his unit has NOT been designed for use in mobile applications, such as: mobile discobars, mobile PA systems, Live bands, audio rental systems, …
PROFESSIONAL POWER AMPLIFIER Connections 1 3 4 5 6 2 11 13 10 12 7 8 9 14 1. C hannel 2 overload led: when this led lights up, you are overloading the input. Lower the input signal immediately to prevent the amplifier from shutting down. 2. C hannel 1 overload led: when this led lights up, you are overloading the input. Lower the input signal immediately to prevent the amplifier from shutting down. 3. C hannel 2 input gain setting.
REVAMP2600 Instruction manual powered up. Full details of the available settings can be found below. 6. Channel 2 speaker output on 2 pole euroblock connector. 7. Channel 1 speaker output on 2 pole euroblock connector. 8. C hannel 2 speaker output on speakon connector. Pin 1+ = speaker 2 +, pin 1- = speaker 2 -. 9. C hannel 1 and 2 stereo speaker output on speakon connector. Pin 1+ = speaker 1 +, pin 1- = speaker 1 -; Pin 2+ = speaker 2+, pin 2- = speaker 2-. 10.
PROFESSIONAL POWER AMPLIFIER Operation 5 1 2 3 4 6 1 1. Removable rack ears for 19 rack mounting. 2. Power switch: after switching on the power, the power led will light up after approx 1 second. The limit-muted leds will light up for a few seconds to avoid excessive power on pop noise. 3. Power led 4. C hannel 1 status led bar and mute switch: when the mute switch is pressed, the orange “LIMIT – MUTED” led will light up.
REVAMP2600 Instruction manual 5. C hannel 2 status led bar and mute switch: when the mute switch is pressed, the orange “LIMIT – MUTED” led will light up. This led will also light up when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals. The “CLIP – OVERLOAD” led indicates that the power amplifier is clipping: reduce the input signal at once whenever this occurs !!! The green “SIGNAL - -40dB” led will light up when an input signal is present.
PROFESSIONAL POWER AMPLIFIER A. LOW impedance applications 1. NORMAL STEREO (no led): default setting for normal stereo operation. 2. CH1 SUB + CH2 TOP (led 1): frequencies below 100 Hz are sent to the sub channel (CH1). Frequencies above 100 Hz are sent to the top channel (CH2). Filter slope is fixed: 12 dB/oct or second order Butterworth characteristic. Audio signal from input 1 is used. 3. CH 1 linked CH 2 (led 4): Both output channels will amplify the signal from the CH1 input. B.
REVAMP2600 Instruction manual impedance applications. The input signal from channel 1 is used for both channels. 8. CH1 full range linked CH2 TRAFO (led 3 + led 4): channel 1 is optimized for low impedance full range loads, channel 2 is optimized for low transformer loads (100 volt applications). The input signal from channel 1 is used for both channels. 9. CH1 TRAFO linked CH2 TRAFO (led 2 + led 3 + led 4): channel 1 and 2 are optimized for transformer loads.
PROFESSIONAL POWER AMPLIFIER !!! IMPORTANT !!! This amplifier relies on convectional and active cooling. In normal situations, overheating will not occur. The unit can be built in a 19 inch rack system, but it is forbidden to block the ventilation holes provided. Therefore, it is absolutely necessary to allow at least one free rack space or 44 mm above and beneath the amplifier. Make sure the ambient temperature is between 0 and 40°C.
REVAMP2600 Instruction manual Technical specifications Dynamic output power 840 W @ 4 Ω Sine wave power per channel 600 W @ 4 Ω (500 msec) Minimum output load impedance CH1 and CH2 4Ω Input connections 2 x balanced euroblock, 2 x balanced XLR, 4 x unbalanced cinch with pass through Input sensitivity 0 dBV / 1V Input impedance 22 kΩ S/N ratio > 98 dB A weighted THD ch. 1/2 < 0.