Ongoing Innovation Introduction > KEY CONSIDERATIONS OF NCPI 2 CAPABILITIES Typical Configurations Cooling and On-site Power Generation Advanced Management Capabilities 4 > COMPUTER ROOMS [ 1-5 RACKS ] 5 > SMALL DATA CENTERS [ 5-20 RACKS ] 6 > MEDIUM DATA CENTERS [ 20-100 RACKS ] 7 > LARGE DATA CENTERS [ >100 RACKS ] 8 Components Power and Power Distribution 2002 > WIRING CLOSETS [ 1-3 RACKS ] 2003 2004 > POWER 10 > COOLING 12 > RACK 14 > MANAGEMENT 16 > SERVICES 18 2005 Beca
On-demand data center. architecture from APC. ..... InfraStruXure™ Network-critical Physical Infrastructure APC has standardized on modular, scalable, open building blocks in developing InfraStruXure™, its ondemand architecture for Network-critical Physical Infrastructure (NCPI). This design method parallels the streamlining of IT systems from mainframes to modular servers, leaving behind the complex electrical and mechanical (NCPI) approach of legacy power and cooling systems.
InfraStruXure I N F R A S T R ™U X U R E meets the 3 key considerations of a strong NCPI: > Higher availability > Increased agility > Lower cost While often ranked as a lower priority issue, the fact is that a high proportion of both capital and operating expenses are allocated to the Network-critical Physical Infrastructure (NCPI). Additionally, the right NCPI provides a key opportunity to improve overall system availability. InfraStruXure™ has been specifically engineered to address these issues.
2 Adapt quickly to changing environments and technologies To respond effectively to changing environments, happen within days or weeks, not months or years. And as power densi- the NCPI must be specified, designed, and ties, cabling densities, and equipment vendors continue to change, the deployed quickly. Unfortunately, it often takes NCPI must be adaptable enough to respond. InfraStruXure’s modular, months to deploy traditional systems.
TYPICAL CONFIGURATIONS Because InfraStruXure™ architecture is easy to customize using standardized components, configurations may vary. Here are five typical InfraStruXure configurations for different size installations. To configure the right InfraStruXure for you, go to page 20.
INFRASTRUXURE FOR COMPUTER ROOMS [ 1 – 5 RACKS ] COMPONENTS POWER RACK COOLING MANAGEMENT 1 Smart-UPS® (not shown) 2 NetShelter® VX Enclosure 4 10 1 Smart-UPS® RT (not shown) 3 1 Symmetra LX Rack PDU (Basic, Metered, and Switched) Rack Air Removal Unit (ARU) 10 NetworkAIR™ PA4000 6 Environmental Monitoring Unit 10 Environmental Management System ® 5 (not shown) (not shown) Rack Accessories (not shown) 5 Door Grille Kit SERVICE InfraStruXure™ Manager A full range of systemand
INFRASTRUXURE FOR SMALL DATA CENTERS [ 5 – 20 RACKS ] COMPONENTS POWER 1 RACK InfraStruXure™ 20kW UPS with Power Distribution Unit (not shown) 1 Symmetra PX 40kW UPS 2 InfraStruXure 40kW Power Distribution Unit 1 XR Battery Enclosure COOLING 5 NetShelter® VX Enclosure 3 Rack PDU (Basic, Metered, and Switched) ® 6 4 Hot-aisle Containment System (not shown) 4 Rack Air Removal Unit (ARU) (not shown) (not shown) 3 Rack Accessories (not shown) MANAGEMENT NetworkAIR™ IR 40kW 7 InfraStruXu
INFRASTRUXURE FOR MEDIUM DATA CENTERS [ 20 – 100 RACKS ] COMPONENTS POWER COOLING RACK 1 Symmetra® PX 80kW UPS 7 NetShelter® VX Enclosure 2 InfraStruXure™ 80kW Power Distribution Unit 4 Rack PDU (Basic, Metered, and Switched) 3 XR Battery Enclosure 4 InfraStruXure Rack Distribution Panel 5 Automatic Transfer Switch with Distribution Panel 6 Standby Power Generator 5 8 (not shown) MANAGEMENT Hot-aisle Containment System (not shown) 5 NetworkAIR™ IR 40kW 5 (not shown) Environmental
INFRASTRUXURE FOR LARGE DATA CENTERS [ >100 RACKS ] COMPONENTS POWER 1 Symmetra® MW UPS 2 InfraStruXure™ 150kW Power Distribution Unit (PDU) 3 4 Automatic Transfer Switch with Distribution Panel COOLING RACK InfraStruXure™ Manager Rack PDU (Basic, Metered, and Switched) Hot-aisle Containment System (not shown) (not shown) (not shown) Rack Air Removal Unit (ARU) (not shown) NetShelter® VX Enclosure 3 3 MANAGEMENT NetworkAIR™ IR 40kW 5 Rack Accessories 6 Environmental Monitoring Unit S
OVERVIEW OF INFRASTRUXURE COMPONENTS InfraStruXure™ architecture has a wide range of integrated components and service offerings.
POWER COMPONENTS Network and Server UPS Smart-UPS® XL UPS or Smart-UPS® RT UPS Smart-UPS® XL UPS Smart-UPS® RT UPS • Matching battery packs can be added to meet changing needs • Double conversion on-line for zero transfer time and tight voltage/frequency regulation • 4th generation line-interactive design provides proven performance • High power density occupies less space and weighs less • Hot-swappable battery replacement system minimizes downtime • Hot-swappable/user-replaceable batteries ensure c
Power Distribution Units Data Center and Facility UPS InfraStruXure™ PDU 40,60,80,150kW Symmetra® PX 40-80kW UPS • N+1 redundant design for high availability • Scalable power and runtime for flexibility and lower cost • Small footprint minimizes real estate expenses for non-IT equipment • User-replaceable modules for ease of service • Wraparound system bypass isolates UPS from critical load* • Rack-based design speeds deployment • Local or Web-based monitoring for ease of management • Front and rear
COOLING COMPONENTS Computer Room Air Conditioning Air Distribution and Fans Rack Air Removal Unit (ARU) NetworkAIR™ IR* • Ducted exhaust system removes hot air to prevent re-circulation and eliminate air mixing • Warmer return air temperature maximizes the capacity of the system for increased efficiency • Power or temperature controlled fan speed ensures proper amount of heat removal • Intelligent, proactive control, and real-time monitoring.
Hot-aisle Containment System Hot-aisle Containment* • Allows for quick deployment of high density clusters • IT equipment can be moved or changed without system reconfiguration • Allows for changing needs and future expansion with a pay-as-you-grow architecture • Sealed hot aisle eliminates mixing with cold supply air increasing availability • Increased cooling capacity and system efficiency from warmer air return temperatures • UPS-supported fans through dual input power to cooling system The Hot-aisle Co
RACK COMPONENTS Enclosures Open Frame Racks NetShelter® VX NetShelter® 2- and 4-Post Open Frame Racks • Ventilated doors with scalable cooling options satisfy varying thermal requirements of rackmounted applications • Offers a generous 43U of 19” equipment mounting space in a 7’ (2133 mm) high design • Available with square holes for servers or threaded holes for networking gear • Recessed power distribution channels provide easy access to multiple receptacles occupying zero U • Optional roof allows
Rack Power Distribution POWER AND DATA CABLE ROUTING Basic Rack PDU • Affordable, simple power in/power out design Traditional power and cooling system • Various amperage options • Both domestic (NEMA) and international (IEC) versions • Variety of horizontal & vertical mounting solutions • Toolless mounting in NetShelter VX Metered Rack PDUs • Current monitoring with alarm thresholds • Network Ready for remote monitoring • Toolless mounting in NetShelter VX • 3-phase and single-phase units available Sw
MANAGEMENT From environmental management and UPS management to server APC management solutions work together and independently, access, APC management solutions increase availability by remotely allowing you to monitor devices locally over existing IT networks or monitoring and controlling easily and economically. the Web, and to be notified of problems within the system via e- Whether managing a single device, multiple devices, or a mixture of mail or pager gateway notifications.
Server Access LCD Monitor KVM Switches • Occupies only 1U of rack space • Manage multiple servers with just one keyboard, monitor and mouse • 15” TFT active matrix screen provides a high quality, flicker-free display • Multi-platform supports any combination of PS/2, USB and Sun computers • Full-size keyboard with 104 full travel keys and integrated number pad • On-screen display of easy-to-use menus to switch between servers • Low power/cooling requirements compared to a comparable CRT monitor solu
SERVICES The typical data center investment spans 11 years, so it’s impor- Using APC Global Services lets you access project engineering tant to choose your investment wisely. InfraStruXure’s standard- expertise gained from years of experience designing and imple- ized, open building-block approach lets you adapt over the life- menting complex infrastructure solutions.
Industry: Education Application: New Data Center “APC customer service continues to be unparalleled in today’s market. APC was incredibly flexible with our everchanging delivery schedule. Our InfraStruXure™ just rolled into place and plugged in, quick and easy. Even with all the extra people, the installation and user training took only four hours. The installation went very smoothly. “Every APC professional was very conscientious, right down to being careful not to scratch the parquet floor.
5 EASY STEPS TO BUILD YOUR INFRASTRUXURE ™ The InfraStruXure™ BuildOut Tool lets you design and specify InfraStruXure solutions using a Web-based configurator. Need an expert site review? Benefit now from configure-to-order systems, speed of design, and the fact that you can configure your solution yourself. Take these 5 easy steps: 1 Specify number of racks (See floor layout below) 2 Define load per rack or total load Go to our APC Authorized/Certified Partner locator at www.apc.
COMPANY PROFILE • For over 20 years APC has advanced new availability technologies through forward-reaching research and development. APC offers presence and • Propelled by real-world experience and a drive towards technological innovation, APC has the experience, scale, partners across the globe, global presence, and stability required to respond to emerg- delivering peace of mind no ing IT availability trends. matter where your needs lie.
The InfraStruXure™ Hot-aisle Containment System is a patent-pending system that cools up to 20kW of blade servers in a single enclosure.