NOTE: In case of extreme algae formation, unplug the pump and fill the reservoir with a commercially available
algaecide. Follow the directions for destroying the algae. After the proper waiting period, dump the algaecide
out of the reservoir. Rinse with water, repeat if necessary. Be careful not to clog the check valve when starting
the pump after cleaning.
Pump Motor Runs With No Discharge
• Inspect the discharge tubing for its full length to make sure it is clear. Check to ensure the tubing end is
not clogged.
• Make sure the check valve is not clogged. If clogged, unplug the pump, remove the fitting, and clean with
mild soap or detergent.
• The discharge port of the impeller chamber may be clogged due to an accumulation of debris.