Rack Power Distribution & Rack Systems Worldwide
Introduction APC by Schneider Electric offers a wide array of standardized Rack Power Distribution Units (PDUs) designed to increase manageability and efficiency in your data center.
Product Feature by Rack PDU by Family/Series Metered Basic Meteredby-Outlet Switched Metered-byOutlet with Switching AP7800 Series AP8800 Series AP8400 Series AP7900 Series AP8900 Series AP8600 Series ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓* ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Outlet level grouping (multiple outlets in same or multiple units follow single command) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ User access control with assign
Basic Rack PDUs APC Basic Rack PDUs provide reliable power distribution via a single input with multiple output receptacles and distributes power from low-amperage, single-phase circuits to higher-power, three-phase solutions. 200 – 240 V Input 100 – 120 V Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Cord Length Output Receptacles APC SKU Vertical, 0U 100 – 120 NAM, LAM 15 A 1.4 kW NEMA 5-15P (14) 5-15 3.
Basic Rack PDUs (continued ...) 400 – 415 V Three-phase Input 208 V Three-phase Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 208 NAM 20 A, 3ø 5.8 kW NEMA L21-20P (42) 5-20 1.0 m AP7562 Vertical, 0U 208 NAM 20 A, 3ø 5.8 kW NEMA L21-20P (42) 5-20 3.0 m AP7592 Vertical, 0U 208 NAM 20 A, 3ø 5.8 kW NEMA L21-20P (21) 5-20 (6) L6-20 1.
Metered Rack PDUs 200 – 240 V Input 100 – 120 V Input Voltage Metered Rack PDUs provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 100 – 120 NAM, Japan 15 A 1.4 kW NEMA 5-15P (16) 5-15 3.0 m AP8831 Vertical, 0U 100 – 120 NAM 20 A 1.
Metered Rack PDUs (continued ...) 400 – 415 V Three-phase Input 208 V Three-phase Input Voltage Mounting U-space Nominal Voltage Vertical, 0U 208 Vertical, 0U 208 Input Circuit Nominal Power Input Plug Type Output Receptacles NAM 20A, 3Φ 5.7 kW NEMA L21-20P (36) 5-20 NAM 20 A, 3Φ 5.7 kW NEMA L21-20P (24) 5-20 (6) L6-20 Vertical, 0U 208 NAM 20 A, 3Φ 5.7 kW NEMA L21-20P (36) C13 (2) 5-20 (6) C19 Vertical, 0U 208 Region AP8863 1.8 m AP8861 1.
Metered-by-Outlet Rack PDUs Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles 100 – 120 V Input Vertical, 0U 100 – 240 Worldwide 16 A 3.3 kW IEC-320 C20* (21) C13 200 – 240 V Input Vertical, 0U 200 - 240 NAM, LAM, Japan 20 A 3.3 kW NEMA L6-20P Vertical, 0U 200 - 240 LAM, EMEA, GCN, APJ 16 A 3.
Switched Rack PDUs Switched Rack PDUs provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management. Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 100 – 120 NAM, Japan 15 A 1.4 kW NEMA 5-15P (16) 5-15 3.0 m AP8931 Vertical, 0U 120 NAM 20 A 1.9 kW NEMA L5-20P (24) 5-20 3.
Metered-by-Outlet with Switching Rack PDUs Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 100-120 NAM, Japan 30 A 2.9 kW NEMA L5-30P (24) 5-20 3.0 m AP8632 208 NAM 20 A 3.3 kW NEMA L6-20P (21) C13 (3) C19 3.0 m AP8659NA3 100 – 240 Worldwide 20 A 3.3 kW IEC-320 C20* (21) C13 (3) C19 Inlet AP8659 LAM, EMEA, GCN, APJ 16 A 3.7 kW IEC-309 16 A (21) C13 (3) C19 3.
Locking IEC Power Cords PDU Input Server Input IEC C14 IEC-C13 Straight IEC C14 IEC-C13 (Three right, three left) IEC C20 IEC-C19 Straight IEC C20 IEC-C19 (Three right, three left) Cord Length Cords per SKU APC SKU 0.6 m 1.2 m 1.8 m 0.6 m 1.2 m 1.8 m 0.6 m 1.2 m 1.8 m 0.6 m 1.2 m 1.
AR3100 NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure TAA AR3104 NetShelter SX 24U 600mm x 1070mm Deep Enclosure SP AR3105 NetShelter SX 45U 600mm Wide x 1070mm Deep Enclosure with Sides Black TAA X SP AR3107 NetShelter SX 48U 600mm Wide x 1070mm Deep Enclosure TAA X SP AR3150 NetShelter SX 42U 750mm Wide x 1070mm Deep Enclosure W X SP AR3155 NetShelter SX 45U 750mm Wide x 1070mm Deep Enclosure with Sides Black SP AR3157 NetShelter SX 48U 750mm Wide x 1070mm Deep Enclosure X
Rack LCD Consoles KVM Switches Rack LCD Consoles APC SKU 17" Rack LCD console AP5717 19" Rack LCD console AP5719 > Ultra-thin 17" or 19" LCD monitor KVM Switches with CAT-5 Type Connection APC SKU 32-port Digital Enterprise IP KVM with Virtual Media, two remote users KVM2132P 16-port Digital Enterprise IP KVM with Virtual Media, two remote users KVM2116P 16-port Digital IP KVM with Virtual Media one remote user KVM1116P > Easy to install 16-port Analog Enterprise KVM with Virtual Media, two
Receptacle and Plug Types Voltage Amps Typical Rating # Wires Plug Name Mating Connector 100 – 120 V 15 A 1.4 kW 3 NEMA 5-15P NEMA 5-15R 20 A 1.9 kW 3 NEMA 5-20P NEMA 5-20R 20 A 1.9 kW 3 NEMA L5-20P NEMA L5-20R 30 A 2.9 kW 3 NEMA L5-30P NEMA L5-30R 15 A 2.5 kW 3 IEC-C14 IEC-C13 16 A 3.7 kW 3 IEC-309 16 A, 2P, 3W IEC-309 16 A, 2P, 3 20 A 3.3 kW 3 IEC-C20 IEC-C19 20 A 3.3 kW 3 NEMA L6-20P NEMA L6-20R 30 A 5.0 kW 3 NEMA L6-30P NEMA L6-30R 32 A 7.
Find out more: The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack PDU at: testdrive.apc.com www.apc.com ©2015 Schneider Electric. All Rights Reserved. Schneider Electric, APC, InfraStruxure, StruxureWare, and NetShelter are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners. • www.schneider-electric.