Rack Power Distribution Worldwide
Introduction APC by Schneider Electric offers a wide array of standardized Rack Power Distribution Units (PDUs) designed to increase manageability and efficiency in your data center.
Rack PDU Product Feature by Family/Series Basic Metered Metered by Outlet with Switching Switched AP7500 AP7800 AP8800 AP7900 AP8900 AP8600 and 9500 Series Series Series Series Series Series Design Features Ultra-low-profile, space-saving design Hydraulic-magnetic circuit breakers (in units configured with circuit breakers) Ultra-low-profile circuit breakers (for units with breakers) Locking IEC receptacles and locking power cord compatible Environmental monitoring port for external temperature/h
Basic Rack PDUs APC Basic Rack PDUs provide reliable power distribution via a single input with multiple output receptacles and distributes power from low-amperage, single-phase circuits to higher-power, three-phase solutions. 200 – 240 V Input 100 – 120 V Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 100 – 120 NAM, LAM 15 A 1.4 kW NEMA 5-15P (14) 5-15 3.
Basic Rack PDUs Continued... 400 – 415 V Three-phase Input 208 V Three-phase Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 208 NAM 20 A, 3ø 5.8 kW NEMA L21-20P (42) 5-20 1.0 m AP7562 Vertical, 0U 208 NAM 20 A, 3ø 5.8 kW NEMA L21-20P (42) 5-20 3.0 m AP7592 Vertical, 0U 208 NAM 20 A, 3ø 5.8 kW NEMA L21-20P (21) 5-20 (6) L6-20 1.
Metered Rack PDUs Metered Rack PDUs provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur. 200 – 240 V Input 100 – 120 V Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 100 – 120 NAM 15 A 1.4 kW NEMA 5-15P (16) 5-15 3.0 m AP7831 Vertical, 0U 120 NAM 20 A 1.9 kW NEMA L5-20P (24) 5-20 3.
Metered Rack PDUs Continued... 400 – 415 V Three-phase Input 208 V Three-phase Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 208 NAM 20 A, 3ø 5.7 kW NEMA L21-20P (42) 5-20 1.0 m AP7862 Vertical, 0U 208 NAM 20 A, 3ø 5.7 kW NEMA L21-20P (42) 5-20 3.0 m AP7892 Vertical, 0U 208 NAM 20 A, 3ø 5.7 kW NEMA L21-20P (21) 5-20 (6) L6-20 1.
Switched Rack PDUs Switched Rack PDUs provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management. 200 – 240 V Input 100 – 120 V Input Voltage Mounting U-space Nominal Voltage Region Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU Vertical, 0U 100 – 120 NAM 15 A 1.4 kW NEMA 5-15P (16) 5-15 3.0 m AP7931 Vertical, 0U 120 NAM, LAM 20 A 1.
Switched Rack PDUs Continued... 400 – 415 V Three-phase Input 208 V Three-phase Input Voltage Input Circuit Nominal Power Input Plug Type Output Receptacles Cord Length APC SKU NAM 20 A, 3ø 5.7 kW NEMA L21-20P (24) 5-20 1.0 m AP7960 NAM 20 A, 3ø 5.7 kW NEMA L21-20P (24) 5-20 3.0 m AP7990 208 NAM 20 A, 3ø 5.7 kW NEMA L21-20P (21) C13 (3) C19 1.8 m AP8961 Vertical, 0U 208 NAM 30 A, 3ø 8.6 kW NEMA L21-30P (21) C13 (3) C19 1.
Rack-mount Transfer Switch Input Voltage Mounting Input Circuit U-space Input Plug Type Output Receptacles Cord Length APC SKU 100 V 100/120 V 120 V 120 V 1 20 A NEMA L5-20P (8) 5-15 2.4 m AP7752J 1 15 A NEMA 5-15P (8) 5-15 2.4 m AP7750A 1 20 A NEMA L5-20P (10) 5-20 2.4 m AP7752 2 30 A NEMA L5-30P (16) 5-20 2.4 m AP7753 1 20 A NEMA L6-20P (8) C13, (1) C19 2.4 m AP7730 2 30 A NEMA L6-30P (16) C13, (2) C19 2.4 m AP7732 2 30 A NEMA L6-30P (1) L6-30R 2.
Rack LCD Consoles KVM Switches Rack LCD Consoles APC SKU 17" Rack LCD console AP5717 19" Rack LCD console AP5719 > Ultra-thin 17" or 19" LCD monitor KVM Switches with CAT-5 Type Connection APC SKU 32-port Digital Enterprise IP KVM with Virtual Media, two remote users KVM2132P 16-port Digital Enterprise IP KVM with Virtual Media, two remote users KVM2116P 16-port Digital IP KVM with Virtual Media one remote user KVM1116P > Easy to install 16-port Analog Enterprise KVM with Virtual Media, two
Receptacle and Plug Types Voltage Amps Typical Rating # Wires Plug Name Mating Connector 100 – 120 V 200 – 240 V 208 V Three-phase 400 – 415 V Three-phase 15 A 1.4 kW 3 NEMA 5-15P NEMA 5-15R 20 A 1.9 kW 3 NEMA 5-20P NEMA 5-20R 20 A 1.9 kW 3 NEMA L5-20P NEMA L5-20R 30 A 2.9 kW 3 NEMA L5-30P NEMA L5-30R 15 A 2.5 kW 3 IEC C14 IEC C13 16 A 3.7 kW 3 IEC 309 16 A, 2P, 3W IEC 309 16 A, 2P, 3 20 A 3.3 kW 3 IEC C20 IEC C19 20 A 3.
Find out more: The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack PDU at: testdrive.apc.com www.apc.com ©2012 Schneider Electric. All Rights Reserved. Schneider Electric, APC, InfraStruxure, StruxureWare, and NetShelter are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners.