Technical information
Chapter 7:
[sPDUOutConfigMSPmups] Outlet Configuration OIDs
PowerNet MIB Reference Guide
62
OID Task
{sPDUOutletConfigMSPmupsTable}
{sPDUOutletConfigMSPmupsEntry}
sPDUOutletConfigMSPmupsIndex
sPDUOutletConfigMSPmupsName
sPDUOutletConfigMSPmupsOutletIndex
sPDUOutletConfigMSPmupsOutletName
sPDUOutletConfigMSPmupsZone1
sPDUOutletConfigMSPmupsZone2
sPDUOutletConfigMSPmupsZone3
sPDUOutletConfigMSPmupsZone4
sPDUOutletConfigMSPmupsP1LowHum
sPDUOutletConfigMSPmupsP1HiHum
sPDUOutletConfigMSPmupsP1LowTemp
sPDUOutletConfigMSPmupsP1HiTemp
sPDUOutletConfigMSPmupsP2LowHum
sPDUOutletConfigMSPmupsP2HiHum
sPDUOutletConfigMSPmupsP2LowTemp
sPDUOutletConfigMSPmupsP2HiTemp
View and configuration a spcifived outlet. (The
sPDUMasterStatusMSPOutletCount OID identifies the number
of table entries.)
• The index to the MasterSwitch Plus unit’s entry (read only).
• The name of the MasterSwitch Plus unit (read only). (You use the
sPDUMasterConfigMSPName OID to define this name).
• The outlet number (read only)
• The name of the outlet (read only). (You use the
sPDUOutletConfigMSPallOutletName OID to define this
name).
• For this outlet, enable or disable any of the alarms for zone 1, 2,
3, or 4 that the Environmental Monitor is monitoring.
- disableAlarm (1): Disable the alarm for the zone number in
the OID name, e.g. to disable the alarm for zone 3, set this
value for the OID sPDUOutletConfigMSPmupsZone3.
- enableAlarm (2): Enable the alarm for the zone number in the
OID name.
• Enable or disable the Probe 1 low humidity alarm for the outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• Enable or disable the Probe 1 high humidity alarm for the outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• Enable or disable the Probe 1 low temperature alarm for the
outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• Enable or disable the Probe 1 high temperature alarm for the
outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• For this outlet, enable or disable the Probe 2 low humidity alarm.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• Enable or disable the Probe 2 high humidity alarm for the outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• Enable or disable the Probe 2 low temperature alarm for the
outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.
• Enable or disable the Probe 2 high temperature alarm for the
outlet.
- disableAlarm (1): Disable the alarm.
- enableAlarm (2): Enable the alarm.