Specifications

• 42U (73.5”-1867mm) storage height for
19” equipment
• 22U (38.5” - 1978mm) storage height for
19” equipment
• Fits through a standard 7’ office door
• Ventilated doors and roof
• Tinted tempered safety glass front door
• Quick release front and rear doors with locks
• Quick release side panels with lock
• Common key for doors and side panels
• Doors are reversible
• Front and rear doors open 180°
• Integrated stabilising feet on 42U (detachable)
• Integrated stabilising plate on 22U (detachable)
• Adjustable levelling feet
• Heavy-duty casters
• Static load capacity=2000 lbs (909 kg)
• Adjustable bottom cable access
• Adjustable vertical mounting rails
• User-friendly rooftop cable access
• Ships fully assembled
• Enhanced cable management
• 60 sets of equipment mounting hardware,
3 Cable Management Hoops, caged nut tool,
hex head wrench and levelling foot wrench are
included with each Premium Enclosure
• 5-year warranty
13
Features include:
Part Number AR1100A
• NetShelter Premium Enclosure
Part Number AR1000A
Part Number AR1001A
A premium enclosure for network administrators providing the ultimate solution for organisation, security,
flexibility, and protection of networking equipment in a datacentre environment.
The NetShelter Premium Enclosure is designed for robust server and networking environments
that require a high quality, feature rich enclosure solution. The NetShelter Premium Enclosure is
a free standing enclosure that saves floor space, organises equipment, eliminates cabling “rat’s
nests” and physically protects your investment. The NetShelter Premium Enclosure is designed
specifically for industry standard (EIA-310-D) 19” rack-mount equipment. Each enclosure provides a
generous 2000 lbs (909 kg) equipment weight rating which meets even the most complex configu-
ration requirements. Each NetShelter Premium Enclosure is powder-coated in a computer beige/dark
grey combination providing an attractive and durable finish. The NetShelter Premium Enclosure is
offered in two sizes. A 42U version is designed for the typical datacentre application where a large
quantity of equipment needs to be rack-mounted into a single enclosure. A 22U version is
designed for branch office locations where space is restricted or where the configuration does
not require a full size 42U enclosure. The 42U enclosure provides 73.5” (1867mm) of equipment
mounting space yet has an overall height of only 81.5”(2070mm). The 22U enclosure provides
38.5” (978mm) of equipment mounting space and an overall height of 46” (1168mm). Both sizes
use the same NetShelter Enclosure Accessories.
The NetShelter Premium series features simple and quick enclosure selection, installation and
equipment access. There’s no need to spend hours selecting from dozens of rack configurations
because APC has made it easy for you by handling the details and providing a complete
enclosure solution right out of the box. The NetShelter Premium Enclosure requires no assem-
bly and rolls through a standard 7 foot office door on its integrated heavy duty casters – there’s
no tipping required. The NetShelter Premium Enclosure is designed with many standard
features that make the enclosure user-friendly. For example, each enclosure has vertical posts
designed with mounting holes along the entire height, allowing for 1U devices to be “zero U
mounted” in the side channel. In addition, the vertical posts are hollow and provide a means for
routing and storing cables. Mounting holes are provided in the roof frame to allow the optional fan
tray to be mounted in a “zero U” position. The front and rear doors have integrated mounting
posts to ensure proper placement of APC’s optional Door Alarm Switch Kit. The Door Alarm
Switch Kit adds a level of security by providing an alarm whenever the doors are breached (when
used in conjunction with APC’s Environmental Monitoring Card).
APC’s AR1000A is the 42U Base enclosure, designed for standalone applications. The AR1001A
is the 42U Expansion enclosure designed for use in a lineup of NetShelter Premium enclosures.
Costing less than the AR1000A Base enclosure, the AR1001A ships with the baying and trim
hardware preinstalled and without side panels. When configuring a multi-bay lineup, customers
should order one AR1000A base enclosure to start the configuration. Then for the remaining
configuration, the AR1001A expansion enclosure(s) should be ordered to accommodate the
additional network devices. Once the installation is complete and all units are bayed together,
the original side panels (from the AR1000A) are used at each end of the lineup to fully enclose
the rack-mounted equipment (see illustration on cover of brochure).
APC’s award-winning Smart-UPS and Symmetra UPSs, power management software, and envi-
ronmental monitoring accessories combine with the NetShelter enclosure to form an integrated
solution ideal for a variety of rack-mount network configurations.