User`s guide
–30–
Menu Item Definitions
MasterSwitch plus
Device
configuration
Continued on next page
Property Description Available Settings
Device Name
A string of characters used to
identify the MasterSwitch plus
unit.
A maximum of
23
printable
ASCII
characters
Default
= unnamed
Power On Time
Delay
The time that MasterSwitch plus
will delay after
AC
power is
applied before starting the
outlet’s power on sequence.
Range
:
0–2:46:39
Default
: 0
Manual Button
Governs whether or not the
manual button functions.
Enabled
: the button functions
accordingtothedescription
in “Manual Button” on
page 11.
Disabled
: no function
Default
: Enabled
Restore Factory
Defaults
Reinstates the original settings
for your MasterSwitch plus unit.
All unit properties are set to the
defaults shown in this table.
Outlet Properties are restored to
the defaults shown on page 12.
(Control Console only)
Enter
Yes
to restore defaults or
E
SC
to cancel request.
View
Manufacturing
Data
Displays the following
information: Model Number,
Manufacture Date, Hardware
Rev, Firmware Rev, and Serial
Number.
Theseitemsareprovidedfor
your information on the Control
Console and cannot be
configured.
View Self-Test
Results
Allowsyoutodisplaytheresults
of the unit’s last power up
self-test. The tests performed
are:
Program Memory: confirms
whether or not the
EPROM
chip is working properly.
Non-Volatile Memory: confirms
whether or not the
EEPROM
chip is working properly.
(Control Console only)
Pass or Fail