Installation and Quick Configuration Temperature/Humidity Expansion Module AP9341
This manual is available in English on the APC Web site (www.apc.com). Dieses Handbuch ist in Deutsch auf der APC Webseite (www.apc.com) verfügbar. Ce manuel est disponible en français sur le site internet d’APC (www.apc.com). Questo manuale è disponibile in italiano sul sito web di APC (www.apc.com). 本マニュアル<各国の言語に対応する>は APC ウェブサイト (www.apc.com) からダウンロードで きます。 Instrukcja obslugi w jezyku polskim jest dostepna na stronie internetowej APC (www.apc.com).
Contents Preliminary Information . . . . . . . . . . . . . . . . . . .1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additional options . . . . . . . . . . . . . . . . . . . 1 Additional documentation . . . . . . . . . . . . . 1 Receiving inspection . . . . . . . . . . . . . . . . . 1 Please recycle . . . . . . . . . . . . . . . . . . . . . . 2 Front and Rear Panel Components . . . . . . . . .3 Front panel . . . . . . . . .
Preliminary Information Overview Connect the Temperature/Humidity Module (TH Module) to the Environmental Manager Main Module to monitor and control the environment through peripheral devices, including temperature and humidity sensors and door contacts.
Preliminary Information Please recycle The shipping materials are recyclable. Please save them for later use, or dispose of them appropriately.
Front and Rear Panel Components Front panel Use the toolless mounting pegs on the front panel of the TH Module to install it in an APC rack or enclosure without using any U-spaces. T/H Expansion Module Item aem0051a Rear panel Description 24 VDC Input Provides supplemental power for high-current load configurations. User Inputs Connect four sensor devices.
Installation—TH Module You can install the TH Module in the front or the rear of the rack or enclosure, using either the rackmount option, which uses 1 U of rack space, or the toolless peg-mount option, which uses no U-space (the toolless peg-mount option is available only with APC racks and enclosures). Toolless peg-mount installation This option may not be available with all racks. Note 1. Slide both mounting pegs into the holes located in the cable channel in the rear panel of the rack. 2.
Installation—TH Module The TH Module occupies one Note U-space. A notched hole (or a number, on newer racks) on the rack’s vertical rail denotes the middle of a U-space. 4. Insert caged nuts (provided with the rack) on the vertical mounting rails above a number at the top of a U-space in your rack and below the same number at the bottom of the U-space. 5.
Installation—Accessories Sensors Selecting a location for the sensor: Install the sensor in a location that represents the air to be monitored. Avoid placing the sensor anywhere that may affect the sensor reading, such as near windows, room entrances, air ducts, other heat sources, or in direct sunlight. To install a sensor on the vertical rail of an APC rack: aem0184a 1. Determine a location on the vertical rail that will allow you to route and secure the 13-ft (4-m) cord neatly. 2.
Installation—Accessories aem0073a 2. Thread a wire tie through the door holes, skipping one hole in the middle. If you have a temperature/humidity sensor, place the sensor in the middle of the wire tie, and pull the wire tie around a ridge on the sensor casing. If you have a temperature sensor, pull the wire tie around the sensor cord, about 1/2-in (1 1/4-cm) from the sensor. 3. Tighten and trim the wire tie. aem0074a 4.
Installation—Accessories Note If you use more than one sensor per rack, route the sensor cord farthest from the middle of the rack first. When routing the sensor cord closest to the middle of the rack, secure all sensor cords in the wire tie. aem0076a 7. With the door fully open, thread the sensor cords through the opening in the front post of the rack. 8. Route the cords between the vertical support rail and the side panel.
Installation—Accessories Alarm beacon 1. Install the alarm beacon in a visible position either on the roof of the rack or inside the rack. 2. If you install the beacon on the roof, route its cable through the provided holes, as shown in the following illustration. 3. Plug the cable into the Alarm Beacon port. 4. The cable may be extended to a maximum of 330 feet (100 m), using RJ-45 couplings and standard CAT5 cables.
Installation—Accessories Connecting TH Modules To connect the Main Module to the TH Module: 1. Connect the first TH Module to either port marked A-Link on the rear of the Main Module, using a standard CAT5 (or equivalent) Ethernet patch cable (APC part number 3827BK-10 or equivalent). Do not use a crossover cable for connection. Note A-Link is an APC proprietary CAN (Controller Area Network) bus.
Installation—Accessories Main Module (AP9340) TH Module (AP9341) TH Module (AP9341) A-Link port used to plug in an APC terminator. Main Module monitoring connected devices. CAT5 (or equivalent) cable connecting to the TH Module. TH Module to be monitored by the Main Module. CAT5 (or equivalent) cable connecting to the next TH Module in the cascading configuration. This port may be used to link to an TH Module or to plug in an APC terminator.
Installation—Accessories Additional TH Modules Add TH Modules to the Main Module to monitor additional racks. The Main Module can support a maximum of 32 TH Modules (with additional power supplies). Adding power supplies: The first time a TH Module receives power, it requests a unique identification address from the Main Warning Module. It uses this address to communicate with the Main Module.
Accessing a TH Module TH Module data automatically appears on the interface of the Main Module to which it is connected. See the Environmental Manager: TH Module User’s Guide, available on the Utility CD or online at www.apc.com, See also for information on configuring devices connected to your TH Module. Upgrading a TH Module When you upgrade the firmware of the Main Module, all TH Modules connected to it are also upgraded if a firmware upgrade is available for them.
Specifications TH Module Electrical Input voltage, nominal 24 VDC; 50–175 mA Maximum total current draw 175 mA Physical Dimensions (H × W × D) 1.74 × 13.25 × 1.74 in (4.42 × 33.70 × 4.42 cm) Weight 1.50 lb (0.70 kg) Shipping weight 4.00 lb (1.80 kg) Shipping dimensions (H × W × D) 2.62 × 17.75 × 8.87 in (6.70 × 45.00 × 22.
Specifications Sensors Temperature (AP9335T) Temperature accuracy ±3ºF (±2ºC), from 32 to 104ºF (0 to 40ºC) Sensor operating temperature 14 to 159ºF (–10 to 70ºC) Maximum length of cable 50 ft (15.
Warranty Limited warranty APC warrants the Temperature/Humidity Module to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser.
Warranty 4. Pack the unit carefully. The warranty does not cover damage sustained in transit. Enclose a letter with your name, address, RMA number and daytime phone number; a copy of the sales receipt; and a check as payment, if applicable. 5. Mark the RMA number clearly on the outside of the shipping carton. 6. Ship by insured, prepaid carrier to the address provided by the Customer Support technician.
Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: • In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness. • In direct patient care.
Radio Frequency Interference Changes or modifications to this unit not expressly approved by the party responsible for compliance could void Warning the user’s authority to operate this equipment. USA—FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. – www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. – www.apc.com/support/ Global support searching APC Knowledge Base and using e-support.