Datasheet

Battery pack containing sealed lead acid batteries Page 3 to 14
Version: 1
Date: October, 13
th
, 2015
Canada
According to WHMIS
2.1 Classification of the substance or mixture:
Very Toxic - D1A
Other Toxic Effects - D2A
Corrosive - E
2.2 GHS label elements:
2.3 Other Hazards
In Canada, the product mentioned above is considered hazardous under the Workplace Hazardous Materials
Information System (WHMIS).
2.4 Other Information
Acid batteries used in APC by Schneider Electric Replacement Battery Cartridges (RBCs) are contained within
cartridges and are sealed, non-spillable design. Under normal use and handling, there is no contact with the internal
components of the battery or the chemical hazards. Under normal use and handling, these products do not emit
regulated or hazardous substances. Misuse of the product, such as overcharging, may result in a discharge of battery
electrolyte. Classification provided is for the battery electrolyte and are only applicable in the event that the
electrolyte is discharged.
SECTION 3: Composition/information on ingredients
3.1 Substances
The material does not meet the criteria of a substance in accordance with regulation (EC) No 1272/2008
Chemical Name
CAS Number
EC Number
Composition (%)
LD50/LC50
Classification OSHA
HCS 2012
Lead
7439-92-1
231-100-4
55,9 63,4 %
NO DATA AVAILABLE
Repr. 1A; STOT RE 1
(Liver, Kidney, Blood,
Nervous system); Carc.
2
Sulfuric acid
7664-93-9
231-639-5
15,8 20,5 %
Inhalation-Rat LC50
510 mg/m³ 2 Hour(s)
Ingestion/Oral-Rat
LD50 2140 mg/kg
Eye Dam. 1; Skin Corr.
1A
1-Propene,
homopolymer
9003-07-0
--
4,8 12,3 %
Ingestion/Oral-Rat
LD50 >8 g/kg
Not Classified
Amorphous/fused
silica
60676-86-0
--
3,7 5,6 %
NO DATA AVAILABLE
Not Classified
Polyvinyl Chloride
9002-86-2
--
2,6 %
NO DATA AVAILABLE
Not Classified
Copper
7440-50-8
231-159-6
2,6 %
NO DATA AVAILABLE
Repr. 2, STOT SE 3:
Resp. Irrit.; Eye Irrit. 2;
Steel
--
--
0,4 %
NO DATA AVAILABLE
Not Classified