User's Manual

Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 / M2-CA
6
Alarms and System Errors
Audible Indicators
Status Icons
Mute: If the line through the speaker icon is illuminated, the audible alarm
has been turned off.
Out: Output voltage, frequency
In: Input voltage.
Automatic Voltage Regulation:
When illuminated, the Back-UPS is compensating for low input
voltage
Estimated Run Time: This indicates the battery runtime minutes that remain
if the Back-UPS switches to battery power.
Load: The total load in watts (W) or percentage(%) used by the devices
connected to the Battery Backup outlets.
Four Beeps Every 30 Seconds
Back-UPS is running on battery. You should consider saving
any work in progress.
Continuous Beeping
Low battery condition and battery run-time is very low.
Promptly save any work in progress, exit all open
applications, and shut down the operating system.
Continuous tone Battery Backup outputs are overloaded.
Chirps every 2 Seconds Battery is disconnected.
Continuous chirping
Battery did not pass the automatic diagnostic test and should
be replaced as early as possible. Pressing the
MUTE button
pauses the chirping.
If these icons are flashing... This may be the problem.
The Back-UPS is overloaded. Disconnect one of the items connected to
the Back-UPS. If the Overload icon stops flashing, the Back-UPS is no
longer overloaded and will continue to operate normally.
The Back-UPS is operating on AC power, but the battery is not
functioning properly. Contact Schneider Electric IT (SEIT) Customer
Service to order a replacement battery. See “Replacement Battery” on
page 10.
The Back-UPS is operating on battery power and the battery power is
getting low. Shut down all connected equipment to avoid losing an
unsaved data. When possible, connect the Back-UPS to AC power to
recharge the battery.
The battery is not connected. See “Connect the Battery” on page 2 to
make sure battery wires are connected properly.