User Manual Back-UPSTM BVN650M1,BVN650M1-CA, BVN900M1, BVN900M1-CA Safety and General Information SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damages. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • This UPS is for indoor use only.
Connect the Battery The Back-UPS is shipped with one battery cable disconnected. Remove the “Stop! Connect the Battery” label that covers the outlets Pull up the battery connector handle. The battery connector is located on the underside of the unit. Turn the battery connector to a 90-degree upright position and push it into the unit.
Model Battery Physical BVN650M1 BVN650M1-CA Type (maintenance-free) Average Life BVN900M1 BVN900M1-CA 12V, 6AH lead acid 12V, 9AH lead acid 3 - 5 years, the number of discharge cycles, poor quality AC power, environmental temperature and humidity may shorten the battery lifetime Charging Time Net Weight 6~8 hours recover to 90% capacity 6.8 lb (3.1 kg) 8.4 lb (3.8 kg) Dimensions, LxWxH 10.79 in x 4.13 in x 5.52 in 27.4 cm x 10.5 cm x 14.02 cm Shipping weight Shipping dimensions, LxWxH 12.
Turn On the Back-UPS Press the POWER button. It will illuminate green and a single short beep indicating that the Back-UPS is on and providing protection for connected equipment. The Back-UPS battery will charge regardless of whether the Back-UPS is switched on or off as long as it is connected to AC power. The UPS will have full runtime capability after the initial 24-hour charging period, connected to AC power.
Voltage Sensitivity Adjustment The Back-UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment. In situations where either the BackUPS or the connected equipment is too sensitive for the input voltage level it is necessary to adjust the transfer voltage. 1. Turn off the UPS while connected to a wall outlet. 2. Press and hold the ON/OFF button for 10 seconds.
Status Indicators Status Power On The Back-UPS is supplying AC power to connected equipment. On Battery Back-UPS supplying battery power to battery backup outlets. Audible Power Button Indicator On illumination Solid green None Audible Indicator Terminates N/A Solid green and flashes twice every 2 seconds. - Using Quick Mute. - Beeping stops when Low Battery notification The Back-UPS is supplying battery power to the battery backup outlets and the battery is near a total discharge state.
Troubleshooting Problem and Possible Cause Solution The Back-UPS will not turn on. The Back-UPS is not connected to AC power, Make sure the power cord is securely connected to the wall there is no AC power available at the wall outlet, and that there is AC power available from the wall outlet, or the AC power is experiencing a outlet. Where applicable, check that the wall outlet is brownout or over voltage condition. switched on.
Wall Mount Installation • • Horizontal installation, use 2 screws 7.63” (194 mm) apart for BVN650M1/ BVN650M1-CA and 9.45” (240 mm) apart for BVN900M1/BVN900M1-CA. Allow 5/16” (8 mm), of the screw to protrude from the wall. Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. 2. 3. 4. 5. 6. 8 Review the Troubleshooting section of the manual to eliminate common problems.
Battery Replacement CAUTION RISK OF HYDROGEN SULPHIDE GAS OR EXCESSIVE SMOKE • Replace the battery at least every 5 years. • Replace the battery immediately when the UPS indicates battery replacement is necessary. • Replace the battery at the end of its service life. • Replace batteries with the same number and type of batteries as originally installed in the equipment.
Warranty Register your product on-line. http://warranty.apc.com The standard warranty is three (3) years from the date of purchase. Schneider Electric IT (SEIT) standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT Technical Support representative.
APC by Schneider Electric IT Customer Support Worldwide For country specific customer support, go to the APC by Schneider Electric Web site, www.apc.com. EMC Compliance This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. ® Select models are ENERGY STAR qualified.
Important UPS Safety Information SAVE THIS GUIDE SAVE THESE INSTRUCTIONS – This manual contains important instructions that should be followed during installation and maintenance of the Schneider Electric equipment and batteries. General Safety Information • This UPS is intended for indoor use only. • For a UPS with a factory installed power cord, connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.