Datasheet

Advanced View: Configuring Pods and Alerts
96 Using Your Appliance
This window features Primary and Backup tabs, each of which has the same fields available. The
settings specified on the Primary tab are used by default for any periodic HTTP reports. The settings
on the Backup pane are used if communication with the Primary server fails.
3. Type the appropriate values in the fields.
4. Specify Advanced Scheduling for the Periodic Report (optional). By default, all Periodic Reports
will be generated according to the Interval value you specify. However, you can specify that a
Periodic Report will be active only occur during specific time ranges. To configure Advanced
Scheduling:
a. Click Advanced Scheduling.... The Advanced Scheduling window opens.
b. By default, all time periods in the schedule are set to Enabled. To disable the Periodic Report for
a currently enabled period of time, highlight the period of time by clicking-and-dragging over the
desired time range, and then click Disable. To enable the Periodic Report for a currently disabled
period of time, highlight the period of time by clicking-and-dragging over the desired time range,
and then click Enable.
Include camera pictures Check this check box to include current image captures by
Camera Pod 120s connected to the appliance in the HTTP post.
Interval The frequency with which HTTP reports will be generated.
Sensor Priority Acts as a filter that can be used to limit the amount of sensor
data that is included with the periodic report. You can select
High, Medium, or Low priority settings:
High: Only sensor data associated with physical sensors that
are integrated with or connected to the appliance are included
in the report. Sensor data associated with remote devices,
such as MIB II data gathered from remote targets using Basic
Device Crawlers and Advanced Data that is gathered using
add-on applications such as Advanced Device Crawlers, is not
included in the report.
Medium: Sensor data associated with physical sensors and
with Advanced Data sensor sets from remote devices (such as
that which is gathered using Advanced Device Crawlers) is
included in the report. Data associated with remote devices
that is not grouped in an Advanced Data sensor set, such as
MIB II data gathered from remote targets using Basic Device
Crawlers, is not included in the report.
Low: Sensor data from all sensors is included in the report.
SSL Options Select from this drop-box the SSL options that will be used for
this post.
Target URL The URL of the web server to which the report will be posted.
Target User ID The user ID that will be used, along with the Target Password,
to gain access to the specified web server.
Target Password The password that will be used, along with the Target User ID,
to gain access to the specified web server.
Confirm Password Type the Target Password here again to confirm the password.
Field Description