Unpacking, Installation, and Customization Manual NetShelter® SX Networking Enclosure U.S. Patent No.
This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Este manual está disponible en español en el CD-ROM adjunto. Ce manuel est disponible en français sur le CD-ROM ci-inclus. Questo manuale è disponibile in italiano nel CD-ROM allegato. 本マニュアルの日本語版は同梱の CD-ROM からご覧になれます。 Instrukcja obs³ugi w jêzyku polskim jest dostêpna na CD. O manual em Português está disponível no CD-ROM em anexo.
Contents Introduction ..................................................................... 1 Safety Warnings and Cautions ...................................... 1 Unpacking the Enclosure ............................................... 2 Component Identification............................................... 3 Removing and Reinstalling Side Panels, Roof, and Doors .............................................................. 5 Side Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Airflow Management ..................................................... 20 Installing Airflow Management Panels . . . . . . . . . . . . . . . . . . . . . . . 20 Airflow Management Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Cable Routing and Cable Management ....................... 23 Adjusting the Vertical 0 U Accessory Channels . . . . . . . . . . . . . . . 23 Removing Vertical Cable Managers . . . . . . . . . . . . . . . . . . . . . . . . . 23 Cable Management Accessories. . . .
Introduction The American Power Conversion (APC®) NetShelter® SX Networking 750-mm wide enclosures are high-quality enclosures for storage of industry-standard (EIA-310), 19-inch rack-mount hardware, which includes servers and voice, data, networking, internetworking, and APC power protection equipment.
Unpacking the Enclosure Disclaimer American Power Conversion is not responsible for damage sustained during reshipment of this product. Receiving inspection Inspect the package and contents for shipping damage, and make sure that all parts were sent. Report any damage immediately to the shipping agent. Report missing contents, damage, or other problems immediately to APC or your APC reseller. Please Recycle The shipping materials are recyclable. Save them for later use, or dispose of them appropriately.
Component Identification Enclosure 1 Adjustable vertical 0 U accessory channel 9 Casters 2 Removable rear split doors : Removable and reversible front door 3 Key for doors and side panels ; APC nameplate 4 Removable side panels with locks < Vertical cable managers 5 Enclosure frame = Mounting flange cable manager 6 Adjustable leveling feet > Vertical mounting flanges 7 Hardware bag (see page 4) ? Roof 8 Airflow management kit (see page 4) NetShelter SX Networking Enclosure — Unpacking
Hardware bag contents Plastic cup washers (60) M6 x 16 Phillips slot screws (60) M5 x 12 screws (4) Torx® T30/#2 Phillips wrench Cage nuts (60) 7-mm hole plugs (4) Cage nut tool Airflow management kit 3-U foam airflow management panel (12 included with 42 U enclosures [AR3140 and AR3340]; 14 included with the 48 U enclosure [AR3347]) 4 1-U foam airflow management panel (4) NetShelter SX Networking Enclosure — Unpacking, Installation, and Customization Manual
Removing and Reinstalling Side Panels, Roof, and Doors na2591a Side Panels Roof ns1724a ×2 NetShelter SX Networking Enclosure — Unpacking, Installation, and Customization Manual 5
Doors Note: Doors self-align on hinge pins when properly reinstalled. ns1750b 1. With the door at a 90-degree angle to the front of the enclosure, position the door over the hinge pins (1). ns1751b 2. Use slight pressure to pull the door away from enclosure; then lower the door. ns1752b 3. Connect the ground wire.
Enclosure Installation Moving the Enclosure Caution: To avoid damaging the enclosure and causing a tip hazard, make sure the leveling feet are up before moving the enclosure. Casters. The enclosure can be moved on its casters with up to 1021 kg (2,250 lbs) of equipment installed. Tip Hazard: Use caution when moving an empty enclosure on its casters. Push the enclosure from the front or back only; the enclosure may be unstable if pushed or pulled from the side.
Leveling the Enclosure Required tools: Phillips screwdriver Level 13-mm open-ended wrench (803-513C) Warning: The leveling feet at the corners provide a stable base if the floor is uneven, but they cannot compensate for a badly sloped surface. na1572a To adjust the leveling feet after equipment has been installed, use the 13-mm open-ended wrench (not provided).
Joining Enclosures Enclosures can be joined with or without side panels installed to provide for alignment and some stability. Caution: Joining enclosures provides limited stability to the enclosures. 1. Remove the front and rear doors. 2. Choose between 24-in centers or 600-mm centers (see the detail view below). 3. Align the enclosures and join them using one M5 x 12 flat-head screw (provided in the hardware bag) per bracket—two brackets for the front and two brackets for the rear. 4. Reinstall the doors.
Reversing the Front Door You can reverse the front door so the door is hinged on the opposite side. Required tools: Torx® T30/#2 Phillips wrench (provided in hardware bag) ns1758b 1. Remove the handle. ns1752b 2. Disconnect the ground wire and then remove the door.
ns1824a 3. Remove and reinstall the hinges on the enclosure frame. ns1825a 4. Remove and reinstall the hinges in the door frame. 5. Reinstall door and reconnect the ground wire. ns1766b 6. Remove and reinstall the latch and washer oriented as shown. The washer is rotated 90 degrees from its original orientation, and the latch is rotated 180 degrees.
ns1779b 7. Reinstall the handle on the door. 8. Remove and reinstall the APC nameplate at the location shown. ns1253b 241.3 mm (9.
Securing the Enclosure For additional stabilization, secure the enclosure to the floor. Use fastener locations on the outside or inside of the enclosure, and choose from the accessories shown below. Accessory Part Number Bolt-down kit AR7701 Attaches to rack and floor internally or externally to provide additional stability without blocking cable access. NetShelter SX stabilizer plate AR7700 Attaches externally to the rack and floor to provide additional stability.
Grounding the Enclosure Each enclosure should be grounded directly to the building ground using one of the designated grounding locations (two M6 threaded inserts) at the top or bottom of the enclosure. • Use a Common Bonding Network Jumper kit (for example, Listed [KDER] Panduit® RGCBNJ660PY or equivalent). • Use paint-piercing washers between ground terminal and enclosure frame or remove paint on frame under ground terminals per NEC NFPA 70 Article 250.12. • Torque screws to 6.9 N-m (60 in-lb).
Equipment Installation Adjusting Vertical Mounting Flanges Vertical mounting flanges come factory-installed on the enclosure in the proper position for use with rack-mountable equipment that has a depth of: • 558.8 mm (22 in) for a 1070-mm deep enclosure • 749.3 mm (29.5 in) for a 1200-mm deep enclosure The mounting flanges are adjustable towards the front or the rear of the enclosure to accommodate different rails or equipment with other depths. The flanges can be adjusted to be as close as 279.
ns0977b 2. Use the Torx T30/#2 Phillips wrench (provided) to loosen—but not remove—the three Torx screws. ns0717c 3. Lower the three flat brackets and move the mounting flange to the desired location.
4. To align the vertical mounting flanges properly, note the symbol (for example, a diamond) visible through one of the three holes on the top of the flange, and ensure that the same symbol is visible through the corresponding hole at the bottom of the flange. Only one symbol is visible at a time through any of the holes. In the factory-standard position, diamonds are visible Vertical mounting flanges placed across from each other must have the same visible symbol.
Installing Equipment Warning: To prevent the enclosure from tipping over after equipment installation: • Make sure you have secured the enclosure to the floor before installing equipment. • Install the heaviest equipment first toward the bottom of the enclosure to prevent the enclosure from becoming top-heavy. • Do not extend equipment on sliding rails until you have installed three or more pieces of similar-sized equipment or until you have installed the stabilizer plate or bolt-down brackets.
Equipment Installation Accessories Accessory Part Number Description Recessed rail kit AR7508 (for a 42 U enclosure) Use the recessed rail kit to install equipment that has a different mounting depth from the other equipment in the enclosure. AR7578 (for a 48 U enclosure) 15 U 42 U 48 U ns1845a 6U AR7510 For NetShelter SX Networking 42 U, 750-mm wide enclosures (AR3140 and AR3340) only, the mounting rails accommodate 23-in rack mountable equipment.
Airflow Management Caution: Improper airflow could damage installed components. Installing Airflow Management Panels 1 U 2 and 3 U 1 foam airflow management panels help isolate hot air and prevent it from entering the cold aisle. Install airflow management panels in the channel along the right vertical mounting flange next to inactive equipment such as patch panels. The left side of the enclosure does not require panels.
Accessory Part Number Description Side Airflow Duct Kit AR7715 The NetShelter Side Airflow Duct Kit is intended for use with Cisco® Catalyst 6509, 6509-E, and 6513 Switches and Cisco MDS 9509 and 9513 Multilayer Switches. For networking switch applications, the Side Airflow Duct Kit allows for improved cable management solutions while maintaining adequate airflow and separation of hot and cold aisles to cool switches.
Accessory Part Number Description KoldLok® raised floor grommet AR7720 (Qty. 10) Designed to seal openings in new raised floor cutouts prior to the installation of communications or power cabling. AR7730 (Qty. 10) AR7740 (Qty.
Cable Routing and Cable Management The NetShelter SX Networking Enclosure has cable access openings on its roof, sides, and bottom. Four vertical cable managers and two Vertical 0 U Accessory Channels are included with the enclosure and APC offers a variety of other cable management accessories. Adjusting the Vertical 0 U Accessory Channels The vertical 0 U accessory channels provide toolless mounting capabilities for APC Rack Power Distribution Units (PDUs) and APC cable containment brackets.
Cable Management Accessories Part Number Description 1 U data distribution panel AR8451 (shown) Holds four data distribution cables, for a total of 24 ports. 2 U data distribution panel AR8452 Holds eight data distribution cables, for a total of 48 ports. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ns1827a Accessory CAT 6 Patch Panel CAT6PNL-24 (shown) 24-port RJ45 to 110 568 A/B color-coded patch panel.
Accessory Part Number Description 19-inch horizontal cable organizers AR8602 (1U) Routes cables horizontally on the front or back of the 19-inch EIA enclosure. AR8600 (2 U) AR8601 (2 U double sided) AR7710 (Qty. 6) Contains cables along the vertical 0 U accessory channel. Installs without tools. Side panel with access holes AR7305 (Qty. 2) For a NetShelter SX Networking 42 U, 1070-mm deep enclosure (AR3140) only. Allows cable pass-through to adjacent enclosures.
Accessory Part Number Description Vertical cable manager AR7717 (Qty. 4) Installs in the vertical mounting flanges and in the vertical 0 U accessory channels. The vertical cable manager has smooth plastic cable guides at 1 U increments to allow patch cords to enter and exit in an organized manner. Vertical cable organizer for NetShelter 0 U accessory channel AR8442 (Qty. 2) Eliminates cable stress by organizing cable layout within the rear channels of the enclosure.
Part Number Description NetShelter SX 42 U vertical cable organizer AR7502 (Qty. 2) NetShelter SX 48 U vertical cable organizer AR7572 (Qty. 2) Installs in the enclosure along the side braces. Provides toolless mounting capabilities for APC Rack Power Distribution Units (PDU) and APC cable containment brackets. Provides tie-off locations for cables. NetShelter SX 42 U narrow vertical 0 U cable organizer AR7511 (Qty. 2) For NetShelter SX Networking 42 U enclosures (AR3140 and AR3340) only.
Description Vertical fiber organizer AR8443A The vertical fiber organizer provides a method to manage fiber cabling within an enclosure and mounts toollessly into the vertical 0 U accessory channel. Fiber organizer spools AR8444 (Qty. 4) Can be mounted toollessly to the vertical fiber organizer or a vertical 0 U accessory channel.
Part Number Description Toolless hook-andLoop cable manager AR8621 (Qty. 10) Includes ten 457-mm (18-in) hook and loop black cable straps that install in the square mounting holes of vertical 0 U accessory channels or vertical mounting flanges.
Specifications AR3340 AR3140 AR3347 Height 1991 mm (78.40 in); 42 U 1991 mm (78.40 in); 42 U 2258 mm (88.90 in); 48 U Width 750 mm (29.53 in) 750 mm (29.53 in) 750 mm (29.53 in) Depth 1070 mm (42.13 in) 1200 mm (47.24 in) 1200 mm (47.24 in) Net weight 155.95 kg (343.10 lb) 161.36 kg (355.00 lb) 185.45 kg (408.00 lb) Total open area (front door) 788 972 mm2 (1,222.91 in2) 788 972 mm2 (1,222.91 in2) 900 417 mm2 (1,395.65 in2) Total open area (rear door) 866 920 mm2 (1,343.
APC Limited Factory Warranty The limited warranty provided by American Power Conversion (APC®) in this Statement of Limited Factory Warranty applies only to Products you purchase for your commercial or industrial use in the ordinary course of your business. Terms of Warranty American Power Conversion warrants its products to be free from defects in materials and workmanship for a period of five years (two years in Japan) from the date of purchase.
IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBLY OF SUCH DAMAGES.
APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. – www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. – www.apc.com/support/ Global support searching APC Knowledge Base and using e-support.