Model H10 H-Type Power Conditioner 990-2216 Copyright © 2005 American Power Conversion All rights reserved. The APC AV logo is a registered trademark of American Power Conversion. All other trademarks are the property of their respective owners.
Safety Information 1. 2. 3. 4. 5. 6. 7. 8, 9. 10. 11. 12. 13. 14. 15. Read this manual - Read all of the safety and operating instructions before installing and operating this device. Keep this manual - Retain this manual, and all of the safety information that came with this device. Warnings - Comply with all warnings presented in this manual, as well as any found on the device. Follow Instructions - Follow all operating and use instruction.
Safety Information (continued) 16. Overloading - Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load to this device does not exceed that which is listed in the Specifications section of this manual. 17. Openings - Do not push any object into the vents provided for cooling, as such an object may come into contact with high-voltage components and cause injury, death, or damage to the device.
Protect Your Investment Congratulations and thank you for selecting and investing in APC's Model H10 Power Conditioner. At APC, we know you have made an intelligent choice sure to reward you for many years. To ensure you receive all the benefits and protection that accompany your purchase, please take a few minutes to fill out and mail the enclosed Warranty Registration Card, or complete the online form at www.apc.com.
iv
Table of Contents Safety Information i Protect Your Investment iii Introduction 1 Proven Expertise…Proven Reliability 1 Safety Precautions 2 Package Contents 2 Unit Power Capacity 2 Features 2 Automatic Voltage Regulation (AVR) 2 Surge Protection 3 Isolated Noise Filter Banks (INFB) 3 DC Trigger 3 Removable Support Feet 3 12 Outlets 3 Sequenced Turn On/Off 3 Front and Rear Panels 4 Front Panel Controls and Indicators 4 Rear Panel Connectors and Circuit Breaker 7 Installation 11 Make Connections 11 Apply Pow
vi
Introduction Congratulations on your purchase of APC’s H10 Power Conditioner (Figure 1). This unit will protect your high performance audio and video (AV) system from damaging power surges, spikes and lightning. Protection is guaranteed. Isolated noise filter banks and Automatic Voltage Regulation (AVR) will eliminate power as a source of audio and video signal degradation. Data-line surge protection jacks will stop surges traveling over phone lines.
Safety Precautions Please ensure you have read and understand all of the safety information located at the front of this manual. If you have any questions about the safety information, or are concerned that your home may not be properly wired for this equipment, please contact APC Technical Support or a qualified and licensed electrician.
Surge Protection The H10 Power Conditioner provides a high level of surge protection for the voltage going into the unit, thus protecting the devices connected to the unit. Additionally, surge protected coax/radio frequency (RF) connectors are protected against surges traveling over coaxial lines to protect your digital satellite system (DSS), CATV box, or cable modem.
Front and Rear Panels The following sections describe the controls and indicators on the front and rear panels. Front Panel Controls and Indicators The front panel controls and indicators for the H10 Power Conditioner are detailed in Figure 2. Each numbered callout refers to the numbered description found immediately below the picture. 1 2 12 3 11 4 10 9 8 5 6 7 Figure 2.
5 Switched On Status Indicator If illuminated, power is on at all outlets except those with a programmed delay. 6 Delayed On Status Indicator If illuminated, power is ‘on’ at those outlets. 7 Line Trim Status Indicator Automatic Voltage Regulation (AVR) is engaged to correct high input voltage conditions. 8 SEQ/AVR Push Button This push button is used to adjust the AVR range of the H10, as well as to set the Delay time for sequenced outlets.
To set the Delay time for the sequenced outlets: Push the SEQ/AVR push button briefly; all LEDs are extinguished, indicating the H10 is in delay programming mode. The LED corresponding to the number of seconds of delay flashes (0s, 6s, 12s). To change the delay time, press the button until the LED corresponding to the desired number of seconds flashes. After releasing the push button, the unit returns to normal status and the normally illuminated LEDs are lit.
Rear Panel Connectors and Circuit Breaker The rear panel connectors for the H10 Power Conditioner are detailed in Figure 3. Each numbered callout refers to the numbered description found in the following pages. 1 2 8 3 4 7 5 6 Figure 2. H10 Rear Panel Connectors Note: All outlets provide surge protection, voltage regulation, and noise filtering.
1 AC-Powered Outlets The H10 Power Conditioner provides for connection of up to twelve (12) AC-powered devices. The outlets are arranged according to the type of filtering protection provided for a given application. These Isolated Noise Filter Banks eliminate electromagnetic and radio frequency interference (EMI/RFI) that can negatively impact sound and video quality. APC recommends you plug your devices into the outlets as marked, in order to assure optimum protection for your equipment.
2 Surge Protected COAX/RF Connectors The H10 provides surge protection for your CATV system, Cable Modem, DSS, or Antenna system. The surge protection feature prevents surges traveling over Coaxial data lines from damaging the system. Connect the coaxial cable from the CATV or Cable Modem provider to the connector marked “IN.” Connect other cable from the connector marked “OUT” to the device being protected (CATV box or Cable Modem).
6 DC Trigger jacks When connected to a component acting as a DC trigger, that component controls turn on/off of the ‘delayed’ outlet banks. The H10 also allows that DC signal to pass through to another connected component. CAUTION: When connecting to the DC Trigger jacks, connect the source of the DC trigger to the IN jack. The OUT jack should be used only as a pass-through. The DC Trigger signal can be short circuited if the input and output cables are reversed.
Installation The installation of the H10 consists of the following steps: 1. Make connections 2. Apply power 3. Set up the H10 Make Connections Prior to connecting equipment to the H10 Power Conditioner, ensure the unit is functional by connecting the AC Power Cord (provided) at the rear panel ( 5 , Figure 3). Once power is applied to the unit, and the unit is powered on, the front panel LEDs will illuminate. Turn the power switch off - all LEDs extinguish.
Set Up the H10 Using the front panel Dimmer and SEQ/AVR push buttons ( 8 and 11 , Figure 2) you can configure the following functions: • Dimmer Function — The Dimmer function allows you to set the front panel LEDs to any of 6 brightness levels. Simply press the push button until the desired setting is achieved.
Technical Specifications The following table contains the specifications for the H10.
CAUTION: When connecting to the DC Trigger jacks, connect the source of the DC trigger to the IN jack. The OUT jack should be used only as a pass-through. The DC Trigger signal can be short circuited if the input and output cables are reversed. The maximum input voltage for the DC Trigger is 30VDC. Do not apply an AC voltage to the DC trigger jacks. Failure to comply with this statement may result in equipment damage. Physical Dimensions (H x W x D) 3.75 x 17 x 9.5” Weight: Unpackaged / Shipping 16.7 lbs.
Troubleshooting This section describes possible causes and solutions for the following problems: • Unit will not turn on. • “Wiring OK Indicator” LED is not illuminated. Unit will not turn on. Probable Cause: Input power cord is not connected properly. Solution: Ensure supplied power cord is connected firmly at both ends. Probable Cause: No power or insufficient power available at the wall outlet. Solution: Ensure the wall outlet has good power by using a voltmeter, or by plugging in another device.
“Wiring OK Indicator” LED is not illuminated. Probable Cause: There are 3 reasons why this LED would not be illuminated: 1. Reversed polarity exists at the wall outlet. 2. Neutral wire is overloaded. 3. Earth ground is missing at the wall outlet. Solution: Operating the unit under such conditions may impact its surge protection performance. Contact an electrician to have them inspect the building or home wiring to fix the problem. Probable Cause: Unit is on but LEDs are turned off.
Technical Support Internet Address: http://www.apc.com/support Email Support: support.apcc.