Specifications
Table Of Contents
- Product Description
- Safety
- Product Overview
- Specifications
- Installation
- Connect Equipment to the UPS
- 1 . Connect equipment to the outlets on the rear panel of the UPS. Do not use extension cords, pl...
- 2 . Connect the UPS to the building utility power. Connect the UPS to a two-pole, three-wire, gro...
- 3 . Press the On/Off button on the front panel of the UPS to apply power to the unit and all conn...
- 4 . To use the UPS as a master on/off switch, turn on all the equipment that is connected to the ...
- Rear Panel Features
- Display Interface
- Overview
- Using the display interface
- Standard menus
- • Operating mode
- • Switched Outlet status, On or Off
- • Efficiency of the UPS
- • Information about the load
- • Battery capacity
- • Estimated runtime
- • Input and output voltage and frequency
- • Information about the last transfer to battery power
- • Self-test results
- • Language
- • Local power quality: Good, Fair, Poor
- • Choose Standard or Advanced menus
- • LCD Display mode, Always On or Power-Saving
- • Audible alarms
- • Reset to Factory Defaults
- • Unit model number
- • Serial number
- • Battery installation date
- • Suggested battery replacement date
- • Replacement Battery Cartridge model number
- • UPS firmware version
- Advanced menus
- UPS Settings
- Start-up Settings
- General Settings
- • 127 Vac
- • 130 Vac
- • 133 Vac
- • 136 Vac
- • 253 Vac
- • 257 Vac
- • 261 Vac
- • 265 Vac
- • 97 Vac
- • 100 Vac
- • 103 Vac
- • 106 Vac
- • 196 Vac
- • 200 Vac
- • 204 Vac
- • 208 Vac
- • High: The UPS will go on battery power more often to provide the cleanest power supply to the c...
- • Low: The UPS will tolerate more fluctuations in power and will go on battery power less often.
- • Never
- • Start-up only
- • Frequency of test (days)
- Main Outlet Group and the Switched Outlet Group
- Overview
- Using the Main Outlet Group and the Switched Outlet Group
- Customize the Main Outlet Group and the Switched Outlet Group
- Network Management Card Settings
- Emergency Power Off
- Service
- 1 . Review the Troubleshooting section of the UPS manual to eliminate common problems.
- 2 . If the problem persists, contact APC Customer Support through the APC Web site, www.apc.com.
- a. Note the model number and serial number, located on the rear of the unit, and the date of purc...
- b. Call APC Customer Support and a technician will attempt to solve the problem over the phone. I...
- c. If the unit is under warranty, the repairs are free.
- d. Service procedures and returns may vary internationally. Refer to the APC Web site for country...
- 3 . Pack the unit in its original packaging. If this is not available, refer to www.apc.com to ob...
- a. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage ...
- b. For the UPS, always DISCONNECT THE BATTERY before shipping in compliance with U.S. Department ...
- c. Internal batteries may remain connected in the XLBP during shipment (if applicable, not all un...
- 4 . Write the RMA# provided by Customer Support on the outside of the package.
- 5 . Return the unit by insured, pre-paid carrier to the address provided by Customer Support.
- Transport the unit
- APC Worldwide Customer Support
- LIMITED WARRANTY

9Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower
Main Outlet Group and the Switched Outlet Group
Overview
The Main Outlet Group and the Switched Outlet Group can be configured to independently turn off, turn
on, shut down, and reboot connected equipment. (These features are not available on the 750 VA units.)
The Main Outlet Group and the Switched Outlet Group can be commanded to do the following:
• Turn off: Disconnect from power immediately and restart only with a manual command
• Turn on: Connect to power immediately
• Shutdown: Disconnect power in sequence, and automatically reapply power in sequence when
utility power becomes available
• Reboot: Shut down and restart
In addition, the Main Outlet Group and the Switched Outlet Group can be configured to do the
following:
• Turn on or off in a specified sequence
• Automatically turn off or shut down when various conditions occur
Note: If the Main Outlet Group and the Switched Outlet Group are not configured, all of the
outlets on the unit will still provide battery back-up power.
Using the Main Outlet Group and the Switched Outlet Group
The Main Outlet Group functions as a master switch. It will turn on first when power is
applied, and shut off last when there is a power outage and battery run-time has been
exhausted.
The Main Outlet Group must be turned on for the Switched Outlet Group to turn on.
1. Connect critical equipment to the Main Outlet Group.
2. Connect peripheral equipment to the Switched Outlet Group.
– Nonessential equipment that should shut off quickly in the event of a power outage to conserve
battery runtime can be added to a short power-off delay
– If equipment has dependent peripherals that must restart or shut down in a specific order, such
as an ethernet switch that must restart before a connected server, connect the devices to
separate groups
– Equipment that needs to reboot independently from other equipment should be added to a
separate group
3. Use the Configuration menus to configure how the Switched Outlet Group will react in the event
of a power outage.
Customize the Main Outlet Group and the Switched Outlet Group
Use the Control menus to change the Switched Outlet Group and the Main Outlet Group settings.