Specifications

8.38
Request the latest literature and guides from Anixter.
1.800.ANIXTER • anixter.com/literature
Power Distribution Units (PDU)
Liebert products from Emerson Network Power
Power, Cooling and Environmental Monitoring
D
./Power Distribution;Rack Power Strips/16312
Index1.Support and Supplies//Power Protection//Power Strip
KNURR PRODUCTS FROM EMERSON NETWORK POWER PR29210V2-216032.eps
For data centers with basic distribution needs, Knurr basic rack PDUs are well
engineered, built to last and deliver simple and expandable distribution in a
robust package.
FEATURES
Single- or 3-phase input power, up to 25 kVA
Single- or dual-input feed
Single-phase output distribution, NEMA 5-20R, single- or 3-phase input power,
up to 25 kVA
Single-phase output distribution, NEMA 5-20R, IEC-C13 and
C19 combination systems
Rack PDU expansion unit for modularity
Panel level monitoring
Multiple configurations and input power options
Extruded casing and full length brass busbar enhance durability and reliability
Available in a wide variety of models and power configurations to meet most
site needs
Power Distribution;Rack Power Strips/16313
I
ndex1.Support and Supplies//Power Protection//Power Strip
LIEBERT PRODUCTS FROM EMERSON NETWORK POWER PR29207V2-216036.eps
These Liebert MPH Managed Rack PDU systems deliver p
ower distribution, monitoring
and control to plug/cord connected IT devices. Liebert MPH Rack PDUs support the
growth in rack electrical needs while meeting the new demands for remote
power management.
FEATURES
Input power: 20 to 30 amp, single- and 3-phase
Output distribution: single-phase NEMA 5-20R, IEC-C13 and IEC-C19;
combination systems
Branch and aggregate rack PDU metering
Environmental sensors: temperature and humidity
Single IP for up to four rack PDUs
Monitor at a branch and strip level
Supports mounting in 19 in. EIA, 42 U rack environments
Vertical, zero U and rack-mount form factors
Slim form factor - place two PDUs in a single rack
Local and remote monitoring
MONITORED ENABLED ONLY
Knurr DI-STRIP
Anixter No. Vendor No. Description
397022 035351011 9 outlet PDU with 5-15R receptacles, 10 ft.
length cord, rack-mount, vertical
397023 035351041 9 outlet PDU with 5-20R receptacles, t-slots,
20 A L5-20P input, vertical mount
397024 035351021 12 outlet PDU with 5-15R receptacles, 15 A
5-15P input, 10 ft. cord, vertical mount
397025 035351031 18 outlet PDU with 5-15R receptacles, 15 A
5-15P input, 10 ft. cord, vertical mount
397026 035351051 12 outlet PDU with 5-20R receptacles, 20 A
5-20P input, 10 ft. cord, vertical mount
397027 035351061 12 outlet PDU with 5-20R receptacles, 20 A
L5-20P input, 10 ft. cord, vertical mount
397028 035351071 12 outlet PDU with 5-20R receptacles, 20 A
IEC C20 input, vertical mount
397029 035351081 24 outlet PDU with 5-20R receptacles, 30 A
L5-30P input, 10 ft. cord, vertical mount
397030 035352011 9 outlet PDU IEC-C13 receptacles, 20 A
L6-20P input, rack mount
397031 035352041 9 outlet PDU IEC-C13 receptacles, 20 A
IEC-C20 input, rack mount
397032 035352051 4 outlet PDU IEC-C14 receptacles, 30 A
L6-30P input, 10 ft. cord, rack mount
More combinations are available; please contact your local sales
representative for further information.
Liebert MPH - Managed Rack PDU
Anixter No. Vendor No. Description
397033 MPH-NBR09AXXC30 Single-phase input/output, nine 5/20,
1U, 20 A rated, L5-20P input,
rack-mount PDU
397034 MPH-NBR09AXXD30 Single-phase input/output, nine 5/20,
1U, 30 A rated, L5-30P input,
rack-mount PDU
397035 MPH-NBV27AXXC30 Single-phase input/output,
27 5/20 vertical, 20 A rated,
L5-20P input
397036 MPH-NBV27AXXD30 Single-phase input/output,
27 5/20 vertical, 30 A rated,
L5-30P input
397037 MPH-NBV27ANXH30 3-phase input/single-phase output,
21 IEC-C13 + 6 5/20 outlets, 3-phase
L21-30P input
397038 MPH-NBV27NOXH30 3-phase input/single-phase output,
21 IEC-C13 + 6 IEC-C19 outlets,
3-phase L21-30P input