Power Distribution Units (PDU)
Liebert products from Emerson Network Power
Power, Cooling and Environmental Monitoring
D
./Power Distribution;Rack Power Strips/16312
Index1.Support and Supplies//Power Protection//Power Strip
KNURR PRODUCTS FROM EMERSON NETWORK POWER PR29210V2-216032.eps
For data centers with basic distribution needs, Knurr basic rack PDUs are well
engineered, built to last and deliver simple and expandable distribution in a
robust package.
FEATURES
• Single- or 3-phase input power, up to 25 kVA
• Single- or dual-input feed
• Single-phase output distribution, NEMA 5-20R, single- or 3-phase input power,
up to 25 kVA
• Single-phase output distribution, NEMA 5-20R, IEC-C13 and
C19 combination systems
• Rack PDU expansion unit for modularity
• Panel level monitoring
• Multiple configurations and input power options
• Extruded casing and full length brass busbar enhance durability and reliability
• Available in a wide variety of models and power configurations to meet most
site needs
Power Distribution;Rack Power Strips/16313
I
ndex1.Support and Supplies//Power Protection//Power Strip
LIEBERT PRODUCTS FROM EMERSON NETWORK POWER PR29207V2-216036.eps
These Liebert MPH Managed Rack PDU systems deliver p
ower distribution, monitoring
and control to plug/cord connected IT devices. Liebert MPH Rack PDUs support the
growth in rack electrical needs while meeting the new demands for remote
power management.
FEATURES
• Input power: 20 to 30 amp, single- and 3-phase
• Output distribution: single-phase NEMA 5-20R, IEC-C13 and IEC-C19;
combination systems
• Branch and aggregate rack PDU metering
• Environmental sensors: temperature and humidity
• Single IP for up to four rack PDUs
• Monitor at a branch and strip level
• Supports mounting in 19 in. EIA, 42 U rack environments
• Vertical, zero U and rack-mount form factors
• Slim form factor - place two PDUs in a single rack
• Local and remote monitoring
MONITORED ENABLED ONLY
Knurr DI-STRIP
Anixter No. Vendor No. Description
397022 035351011 9 outlet PDU with 5-15R receptacles, 10 ft.
length cord, rack-mount, vertical
397023 035351041 9 outlet PDU with 5-20R receptacles, t-slots,
20 A L5-20P input, vertical mount
397024 035351021 12 outlet PDU with 5-15R receptacles, 15 A
5-15P input, 10 ft. cord, vertical mount
397025 035351031 18 outlet PDU with 5-15R receptacles, 15 A
5-15P input, 10 ft. cord, vertical mount
397026 035351051 12 outlet PDU with 5-20R receptacles, 20 A
5-20P input, 10 ft. cord, vertical mount
397027 035351061 12 outlet PDU with 5-20R receptacles, 20 A
L5-20P input, 10 ft. cord, vertical mount
397028 035351071 12 outlet PDU with 5-20R receptacles, 20 A
IEC C20 input, vertical mount
397029 035351081 24 outlet PDU with 5-20R receptacles, 30 A
L5-30P input, 10 ft. cord, vertical mount
397030 035352011 9 outlet PDU IEC-C13 receptacles, 20 A
L6-20P input, rack mount
397031 035352041 9 outlet PDU IEC-C13 receptacles, 20 A
IEC-C20 input, rack mount
397032 035352051 4 outlet PDU IEC-C14 receptacles, 30 A
L6-30P input, 10 ft. cord, rack mount
More combinations are available; please contact your local sales
representative for further information.
Liebert MPH - Managed Rack PDU
Anixter No. Vendor No. Description
397033 MPH-NBR09AXXC30 Single-phase input/output, nine 5/20,
1U, 20 A rated, L5-20P input,
rack-mount PDU
397034 MPH-NBR09AXXD30 Single-phase input/output, nine 5/20,
1U, 30 A rated, L5-30P input,
rack-mount PDU
397035 MPH-NBV27AXXC30 Single-phase input/output,
27 5/20 vertical, 20 A rated,
L5-20P input
397036 MPH-NBV27AXXD30 Single-phase input/output,
27 5/20 vertical, 30 A rated,
L5-30P input
397037 MPH-NBV27ANXH30 3-phase input/single-phase output,
21 IEC-C13 + 6 5/20 outlets, 3-phase
L21-30P input
397038 MPH-NBV27NOXH30 3-phase input/single-phase output,
21 IEC-C13 + 6 IEC-C19 outlets,
3-phase L21-30P input