Owner`s manual
15
Tubing color:  Clear tubing. Connect the CLEAR tubing from the faucet base stud to the Stage-5 filter’s 
outflow end at point H. (See “Flow -->” arrow on the filter for flow direction.)
Fitting type:  Plastic compression nut fitting with built-in sleeve. No teflon tape needed here.
6. Point G  Stage-5 filter’s T-fitting connection:
Tubing color:  Yellow tubing. Connect the YELLOW tubing to Stage-5 filter’s T-fitting.
Fitting type:  Plastic compression nut fitting with built-in sleeve. No teflon tape needed here.
7. Point Y  Tank’s input & output connection:
Prepare tank:  See Fig. 12. Apply Teflon tape to tank’s threaded Output stem on top of tank (remove 
rubber cap if there is one).
  Screw tank Valve onto Output stem.
Tubing color:  Yellow tubing. Connect the YELLOW tubing from Stage-5 T-fitting to the tank’s valve.
Fitting type:  Quick-Connect fitting on ball valve. Simply push Yellow tubing into valve port.
 Standard 4-gallon Tank Diagram:
        Tank Ball Valve
Fig. 12 
   OFF Position       ON Position
Option: Ice-maker Connection
If you want to connect product water from the RO to your ice-maker, you will need:
 One T-fitting, preferably the quick-connect type fitting
 Extra ¼ “ tubing long enough to go from the RO system to your ice-maker
 Optional: One shut-off valve, preferably the quick-connect type.
See Fig.11. Before connecting the product water line from Point Z to H, add a T-fitting near 
point H to divert product water to both the ice-maker and the faucet. 