Datasheet

Double pole Double pole NC
Normally closed + single pole NO
APEM www.apem.com 1
New!
A02ES-H series
High-security emergency stop switches
Distinctive features and specifications
ELECTRICAL SPECIFICATIONS
• Electrical function : push to shut off, pull or twist to release
• Current/voltage rating - NC contacts :
AC-12, 3A 250VAC
AC-15, 1,5A 250VAC
DC-12, 2A 30V
DC-13, 1A 30V
• Current/voltage rating - NO contacts :
AC12, 0,6A 250VAC
AC14, 0,3A 250VAC
DC12, 2A 30V / 1A 30V
• Electrical life : 100.000 cycles
• Insulation resistance : 100 M min.
• Dielectric strength : contact block 2.500 Vrms
• Contacts : gold plated silver
GENERAL SPECIFICATIONS
• Panel thickness : 6 mm (.236) max.
• Low level or mechanical life :
250.000 cycles
• Recommended torque : 2Nm
• Switch terminals : M3 screws
OPERATING FORCE
• Push to shut off : 32N
• Pull to release : 21N
• Turn to release : 0,27Nm
• Minimum force to direct opening
action : 80N
AGENCY APPROVALS
EN 60947-5-5
EN 60547-5-1
ENVIRONMENTAL SPECIFICATIONS
• Front panel sealing : IP65
• Terminals IP20 (finger safe)
• Operating temperature : -25°C to +60°C
• Storage temperature : -45°C to +80°C
PANEL CUT-OUT
The company reserves the right to change specifications without notice - Not for sale in JAPAN.
Mounting accessories : Standard hardware supplied : 1 nut and 1 flat panel seal
Packaging unit : box of 1 piece with instruction sheet. Instruction sheet also available on request.
UL 508
UL 991
CSA 22.2 No 14
Approved to EN 60947-5-5, EN60547-5-1, UL 508 and CSA
Pull or twist to release
AC-12, 3A 240VAC / DC-12, 2A 30V
Panel sealed to IP65
Built-in-safety
The A02ES-H series has been designed to ensure the highest security level. By design, this product has a failsafe modular
construction.
Many other emergency stop switches are not failsafe and rely on butt action contacts: the NC contats remain closed until the
actuator is pressed. Therefore, if the switch is damaged, destroyed or assembled incorrectly, the contacts remain closed.
On the A02ES-H, if the operator or switch block become separated, the circuit will open.