NORMAL OPERATION LOCK INDICATIONS Aperio™ eForce® A100 Narrow Stile Keyless Entry NORMAL OPERATION HUB INDICATIONS Owner’s Manual & Installation Instructions For Models A100-3090H Adams Rite Manufacturing Co. 10027 S. 51st St. Suite 102 Phoenix, AZ 85044 Phone: 800-872-3267 Fax: 800-232-7329 www.adamsrite.com June 2013 20 80-0180-347 Rev. A Adams Rite Manufacturing Co. Phone: 800-872-3267 www.adamsrite.
Table of Contents TROUBLESHOOTING Warning .............................................................................................. 3 The eForce A100 LED is normally off until a credential is presented and then LED will momentarily turn green if credentials are valid. A red LED will show if credentials are not valid. Definitions ........................................................................................... 3 System Overview ..........................................................
LIMITED WARRANTY Adams Rite Manufacturing Co. (hereinafter ADAMS RITE) manufactures its products in a manner to be free of defects.
SYSTEM OVERVIEW STEP 8 The A100-3090H electrified trim provides access control to narrow stile aluminum doors when combined with an access control system and Adams Rite locking hardware. The A100-3090H includes an integrated iCLASS or PROX reader and electrified lever. The lever handle will not engage the deadlatch or deadbolt until authorization is received wirelessly from the access control system. The A100-3090H is connected to the access control system through the included wireless Aperio hub.
STEP 7 OPERATIONAL DESCRIPTION Mounting the A100-3090 Insert the properly dimensioned spindle into the output hub. Mount the A100 onto the mounting bracket and guide the spindle into the Cam Plug. The A100 must sit flush on the door surface. Credential Card Operation When a user presents a supported credential to the lock, the Aperio system is designed to send the credential wirelessly to the Aperio Hub. The Aperio Hub then communicates with an EAC system.
STEP 6 HUB LOCATION REX/DPS CABLE INSTALLATION Choose the Hub location The hub should be mounted near the top of a wall, on the ceiling or above the ceiling to reduce potential for interference. For a stable and reliable radio link, it is recommended that the hub is located within fifty (50) feet of the lock.
STEP 5 MORTISE CYLINDER INSTALLATION FIG. 14 Using a Philips Head Screwdriver, remove the eight (8) #10-32 x 5/8” screws on the back of the eForce® and gently lift the back plate off the housing. CAUTION! There are wires connecting the housing and back plate assembly. Handle with care. Do not over-tighten! Install Cylinder into housing. Secure and fasten with supplied locking ring using locking ring spanner tool. (FIG.
TRIM INSTALLATION TOOLS & EQUIPMENT STEP 4 HANDING THE eForce® The eForce® is shipped in a non -handed neutral position with the access cover off as shown. IMPORTANT NOTES: The A100-3090H-C/P-01, and A100-3090H-CK/PK-01 are designed exclusively for latching hardware including: Adams Rite 4500/4900 Deadlatches; Adams Rite 8000 Series Exit Devices; Yale 7200 Series Narrow Stile Exit Devices; Corbin Russwin ED4000 Series, and SARGENT 8500 Narrow Design Rim Exit Devices.
RIM Exit Device Application: FIG. 10 A100-3090H for 8700/8800 On the back side of the exit device, remove only the lower Phillips head screw, depending on hand of door, to free up the cylinder actuator for use. (FIG. 10) STEP 1 DOOR PREPARATION FIG. 2 CYLINDER ACTUATOR SCREW MS 1850 Application: A100-3090H for MS® Series Deadbolt Two (2) brass hex head screws and the set screw from the MS1850 will fasten the cam plug to the MS1850. (FIG.
STEP 2 SPINDLE PREPARATION STEP 3 (For 1-3/4” doors) For Adams Rite MS1850 Deadbolts, 4500/4900 Deadlatches, & 8000 Series Mortise Exit Devices: Snap-off spindle at fifth (5th) notch as shown in FIG. 4. For 2” thick door add one notch. Fifth notch CONFIGURE FOR LOCK SERIES Mortise Latch Application: A100-3090H for 4500/4900 (including 8300/8400 Exit Devices) Configure the supplied cam plug to match the hand of door. Insert into latch case with notch on the cam plug aligned with latch case set screw.