Installation Instructions

June 2013 4 80-0180-347 Rev. A
SYSTEM OVERVIEW
The A100-3090H electrified trim provides access control to narrow stile alumi-
num doors when combined with an access control system and Adams Rite
locking hardware.
The A100-3090H includes an integrated iCLASS or PROX reader and electri-
fied lever. The lever handle will not engage the deadlatch or deadbolt until
authorization is received wirelessly from the access control system. The
A100-3090H is connected to the access control system through the included
wireless Aperio hub. The hub connects to the access control system with
Wiegand wiring and signal wiring for REX, DPS, Tamper and Low Battery.
The Aperio™ eForce
®
will mechanically interface with: Adams Rite MS Series
Deadbolts; Adams Rite 4500/4900 Deadlatches; Adams Rite 8000 Series Exit
Devices; Yale 7200 Series Narrow Stile Exit Devices; Corbin Russwin
ED4000 Series, and SARGENT 8500 Narrow Design Rim Exit Devices.
OPERATIONAL SPECIFICATIONS
IEEE 802.15.4 UHF Interface operating at 2.4GHz
iCLASS or PROX Reader technology
AES 128 bit encryption
4-AA battery operated
Operating Temperature Range: -31° to 150°F (-35° to 65°C)
Operating Humidity Range: 5% to 95% relative humidity non-condensing
June 2013 17 80-0180-347 Rev. A
STEP 8 BATTERY INSTALLATION
Properly insert 4 (AA) Alkaline
batteries into battery holder ob-
serving the polarity markings.
Plug battery pack into eForce
®
connector (FIG. 22).
Insert battery case into the
eForce
®
as shown (FIG 23).
Slide battery cover over the bat-
teries.
A battery moisture shield is pre-
installed at the factory to protect
the batteries from the elements.
Insert 5/64” Allen key (included)
and turn clockwise two full turns
to secure the battery cover.
(FIG. 24).
Aperio is activated when battery
cover is installed and secured.
The eForce A100-3090H will self
-test and beep once upon instal-
lation of the batteries.
FIG. 22
FIG. 23
FIG. 24