June 2013 6 80-0180-347 Rev. A
HUB LOCATION
Choose the Hub location
The hub should be mounted near the top of a wall, on the ceiling or
above the ceiling to reduce potential for interference.
For a stable and reliable radio link, it is recommended that the hub is
located within fifty (50) feet of the lock. A maximum of two interior
walls between the hub and
lock is recommended
Recommended locations:
A: Wall Mount
B: Ceiling Mount
C: Above Ceiling Mount
*Note the Hub is not
rated for use in Plenum
spaces
Mounting the Hub
The included hub mounting adapter plate can be used to mount the
hub on a single or double gang box.
A
B
C
June 2013 15 80-0180-347 Rev. A
STEP 6 REX/DPS CABLE INSTALLATION
PIN #
WIRE COLOR
FUNCTION
CONTACT
1
Yellow
D.P.S.
(Door Position
Switch)
N.C.
2
Blue COM
3
Brown N.O.
4
Orange N.C.
REX
(Request to Exit)
5
White COM
6
Green N.O.
Using a Phillips Head screwdriver, remove the eight (8) #10-32 x
5/8” screws on the back of the eForce and gently lift the back plate
off the housing. (Fig. 16).
Plug the Rex/DPS cable into the board and run the other end of the
cable through the grommet and out of the backplate as shown in
Figure 17.
Gently place back plate on housing and secure with eight (8) #10-32
FIG. 16 FIG. 17 FIG. 18