TRIM INSTALLATION TOOLS & EQUIPMENT
IMPORTANT NOTES:
The A100-3090H-C/P-01, and A100-3090H-CK/PK-01 are designed exclu-
sively for latching hardware including:
Adams Rite 4500/4900 Deadlatches;
Adams Rite 8000 Series Exit Devices;
Yale 7200 Series Narrow Stile Exit Devices;
Corbin Russwin ED4000 Series, and
SARGENT 8500 Narrow Design Rim Exit Devices.
The A100-3090H-C/P-02 & A100-3090H-CK/PK-02 are compatible with
Adams Rite MS
®
Series Deadbolts only! THESE UNITS ARE NOT IN-
TERCHANGEBLE.
These instructions, and the fasteners supplied, apply to metal door
applications.
Other door types will need fasteners designed for the
given medium.
TOOLS NEEDED:
Common hand tools such as center punch, drill gun, ¼”
drill bit, Phillips screwdriver, pliers, slotted screwdriver,
pencil.
ADDITIONAL EQUIPMENT NEEDED:
An approved credential card for verification.
Mortise Cylinder - 1” to 1½” in length range with MS cam (Fig. 1). (Note: 1”
cylinders require a 1/8” trim ring).
SUPPLIED PARTS:
NOTE: A cam plug is supplied for either the 01 model latch or 02 model lock.
THIS PRODUCT MUST BE
INSTALLED ACCORDING
TO ALL APPLICABLE
BUILDING AND LIFE
SAFETY CODES
Item Description Qty.
1 Mounting Bracket (Part # 22-9076) 1
2 #10-32 X 5/8” Phillips Pan Head Screws w/Lockwasher 4
3 Spindle (Part # 22-9154) 1
4 5/64” Allen Key 1
5 Cylinder Locking Ring (Part # 24-0061) 1
6 Locking Ring Spanner Tool (Part # 22-0594) 1
FIG. 1
June 2013 13 80-0180-347 Rev. A
STEP 4 HANDING THE eForce
®
The eForce
®
is shipped in a non
-handed neutral position with
the access cover off as shown.
To hand the eForce
®
, rotate the
handle until it clicks into the
horizontal position.
Proceed to step 5 if installing
the A100-3090H-C/P-02 &
A100-3090H-CK/PK-02!
The output hub, located on the
back of the eForce
®
, is shipped
with a clockwise rotation as
viewed from rear. In some in-
stances, this rotation must be
changed to match the device
and/or hand of the door (refer to
Handing Setup Chart).
To change rotation, insert a flat
screwdriver into the output hub
(FIG. 13) located on the back
of the eForce
®
and turn approxi-
mately 270° Clockwise or
Counter Clock-wise.
This will reconfigure the unit to
the opposite rotation.
FIG. 13
NOTE:
Hubs that have (+) shape are for use with deadlatches & exits only.
Hubs that have (-) shape are for use with deadbolts only.
HANDING SETUP CHART
DEVICE TYPE
LEFT HAND REVERSE
ROTATION
RIGHT HAND REVERSE
ROTATION
SVR CLOCKWISE CLOCKWISE
Mortise Latch COUNTER-CLOCKWISE CLOCKWISE
CVR CLOCKWISE CLOCKWISE
Rim COUNTER-CLOCKWISE COUNTER-CLOCKWISE