Aperio® AH20/AH30 Hub Installation Guide Experience a safer and more open world 1
AH20/AH30 - Table of Contents AH20/AH30 - FCC and ISED Canada Statements............................................. 3 AH20/AH30 - Placement of Communication Hub.......................................... 5 AH20/AH30 - Mounting, Americas Adapter Plate........................................... 6 AH20/30 - Mounting, Bottom Cover................................................................... 7 AH20 (J101) - Connections....................................................................................
AH20/AH30 - FCC and ISED Canada Statements FCC Statements Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.
AH20/AH30 - Placement of Communication Hub <2 5m /~ 80 ft AH20/30 - Placement of the Hub, 1 door Note: AH20/AH30 can be installed with an Aperio bottom cover or Americas adapter plate. <2 5m /~ 80 ft AH30 (RS485 Hub) - Placement of the Hub, 1-16 doors Note: AH20/AH30 must be installed into a junction box ex European 2-Gang, Aperio bottom cover or with Americas adapter plate to junction box. AH20/AH30 must be installed by qualified and trained personal.
AH20/30 - Mounting, Americas Adapter Plate (US version) AH40 - Mounting, Americas Adapter Plate 1 Americas Adapter Plate 2 3 Screw (4 x 35 mm) 4 5 Screw (3 x 10 mm) Top Cover Option External Antenna 6
AH40 - Mounting, Bottom Cover AH20/30 - Mounting, Bottom Cover (EU version) 1 Screw (4 x 35 mm) 3 Bottom Cover 2 Screw (3 x 10 mm) Top Cover Option External Antenna 7
AH20 (J101) - Connections S100 J100 EXT TERM NCL1 8 7 6 5 4 3 2 1 1 S700 A0 A1 A2 A3 A4 NOP1 INT 2 3 4 NCL2 A COM2 B NOP2 D1 NCL3 D0 COM3 RED NOP3 GREEN NCL4 GND COM4 8-24VDC J101 NOP4 OFF ON COM1 AH20 Advanced Wiegand Connectors (J101) S100 EXT TERM S700 A0 A1 A2 A3 A4 INT A B D1 D0 RED GREEN GND 8-24VDC J101 AH20 Standard Wiegand Connectors (J101) Note: The installation must comply with national wiring regulations.
Communication Hub hardware version AH20 has four Wiegand signals plus power supply. The purpose and connection of these signals are described in the table below. Hub Connector D1 D0 Description Wiegand Data 1 signal. Output from Communication Hub. Used to transmit credentials. Wiegand Data 0 signal. Output from Communication Hub. Used to transmit credentials. Wiegand Red LED signal. Input to Communication Hub. Used RED for access decision. Leave unconnected if DIP switch 1 is selected “OFF”.
AH20 Advanced Wiegand (J100) - Connections S100 J100 EXT TERM NCL1 8 7 6 5 4 3 2 1 1 S700 A0 A1 A2 A3 A4 NOP1 INT 2 3 4 NCL2 A COM2 B NOP2 D1 NCL3 D0 COM3 RED NOP3 GREEN NCL4 GND COM4 8-24VDC J101 NOP4 OFF ON COM1 AH20 Advanced Wiegand Connectors (J100) 10 Relays Description Relay 1 DPS (Door Position) Relay 2 RX (Request to exit) Relay 3 Battery Alarm Output Relay 4 Tamper Alarm Output/ Lock Jammed Relay Contacts Description NCL Normally Closed COM Common NOP No
AH20 - DIP Switch Configuration Table (S700) DIP Switch Number Label Description Controls use of Red LED signal for access decision. 1 A0 ON => Red LED is used. OFF => Red LED is ignored. 2 A1 Set to OFF by default. Reserved for future use. Controls addition of parity bits if required. 3 A2 ON => Addition of parity bits is enabled. OFF => Addition of parity bits is disabled. Credentials are transmitted as received. Controls byte order of transmitted credentials.
AH30 (J101) - Connections S100 EXT TERM 8 7 6 5 4 3 2 1 OFF ON S700 A0 A1 A2 A3 A4 INT A B D1 D0 RED GREEN GND 8-24VDC J101 AH30 (J101) Connectors Hub Connector Description A RS485 Data A. B RS485 Data B. GND GND = Signal ground. Should be connected to EAC system GND and power supply GND. 8-24 VDC Power supply input, 8-24 VDC, 2 W (AH20 Advanced) alternatively 0.8 W (AH20 Standard and AH30). Note: The installation must comply with national wiring regulations.
AH30 - DIP Switch Configuration Table (S700) DIP Switch Number Label Description Controls RS485 addressing BIT 0-BIT 4. ON => Address bit set. 1-5 A0-A4 OFF => Address bit NOT set. See AH30 - RS485 Addressing Reference on page 13. Control use of termination resistor between RS485 A and RS485 B. 6-7 TERM For termination to be enabled, both switches must be set to ON. ON =>120 Ohm termination resistor connected/ enabled. OFF => 120 Ohm termination resistor disconnected/ disabled.
AH30 - RS485 Bus Connection Here are examples of connection of multiple Communication Hubs to a single RS485 bus of an EAC system. Termination should be enabled to the last Hub on the bus. A B EAC system A B Hub 1 DIP 6 OFF DIP 7 OFF Termination enabled A B Hub 2 DIP 6 OFF DIP 7 OFF A A B Hub 1 DIP 6 ON DIP 7 ON A B EAC system Termination enabled A B Hub 2 DIP 6 ON DIP 7 ON Communication Hub Connections, examples Note: The RS485 bus cable should be of type twisted pair.
AH30 - RS485 Addressing Address A0 0 1 ON ON ON ON ON ON ON ON ON ON 8 9 ON ON 10 11 ON ON ON ON ON ON 12 13 ON ON ON ON ON ON ON ON ON ON ON 14 15 A4* ON 6 7 A3 ON 4 5 A2 Pairing Active* 2 3 A1 ON Address examples *) Note: If any of the A0-A4 DIP switches are moved from OFF to ON within 10 seconds from boot up and the Hub LED is lit, all paired devices will be unpaired.
Address A0 A1 A2 A3 16 17 ON ON 18 19 ON ON ON ON 22 23 ON ON ON 20 21 ON ON ON ON ON ON ON ON ON ON 24 25 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 28 29 ON 30 31 ON Address examples *) A4 is only supported on AH30 in 1 - 1 mode.
AH20/AH30 - Communication Hub LED Indication The Communication Hub has a single LED that supports an optical scheme with red, green and yellow.
AH20/AH30 - Technical Data Physical Dimensions 82 mm x 82 mm x 37 mm (H x W x T) Power Supply 8-24 VDC Power Rating The power supply shall be able to deliver minimum 2 W (AH20 Advanced) alternatively 0.8 W (AH20 Standard and AH30) and be 3 A over current protected. Wire requirements 16-22 AWG. Radio Standard IEEE 802.15.4 (2400 – 2483,5MHz) 16 channels (11-26) AES 128 bit encryption Receiver Sensitivity -100 dBm Wireless Transmit Power 10 dBm/MHz.
NOTE 19