User's Manual

8–27070-20000340-01 Rev A
CHAPTER 8. MANAGEMENT INTERFACES
FAULT REPORTING
The PacketWave Base Station Units and subscriber Indoor Units can be configured to
report events by several means:
Email event messages.
SNMP traps.
Logging to a Syslog server.
Event logs presented on request via SNMP or Web GUI.
Reported events are identified in Table8-A.
Table8-A Reported Events
Fault Event Description
Cold Start BSU, WSS, or subscriber Indoor Unit has performed a full hardware boot.
Warm Start BSU, WSS, or subscriber Indoor Unit has performed a software reboot.
Authentication Failure Invalid user name or password?
Port N Link Down WSS port (number N) has gone down.
Port N Link Up WSS port (number N) has come up.
BSU Up BSU has started normal operation.
BSU Down BSU has ceased normal operation.
CPE Sync Acquired BSU has acquired wireless channel synchronization with a specific subscriber
Indoor Unit.
CPE Up Subscriber Indoor Unit has started communication with the BSU.
CPE Down Subscriber Indoor Unit has ceased communication with the BSU.
DHCP Failed A failure has occurred in the retrieval of required data from the DHCP server.