User's Manual

Chapter 1. Overview
1–8
070-20000750-01 Rev A
Cable Installation
There is one cable for Ethernet connection and two cables that connect the Indoor Unit to
the Outdoor Unit:
A RG-6 quad shield coaxial cable for the subscriber signal (which also provides DC
power to the Outdoor Unit).
A shielded outdoor-rated Cat 5 cable for controlling the Outdoor Unit.
CAUTION: Always power off the Indoor Unit before connecting or disconnecting the
cable from the Outdoor Unit.
Table 1-B provides the types of cable required for the PacketWave 600 Series. For the Out-
door Unit to be located more than 50m (165 ft) from the Indoor Unit, the Radio Signal cable
has to be RG-6 quad shielded with copper center and the Radio Control cable has to be
CAT 5E.
Table 1-B PacketWave 600 Series Cable Requirement
CAUTION: Specific models of cable are listed in a document titled
Cables for Pack-
etWave Product.
This document is included in the CD that shipped with
the equipment.
Connection — Qty Cable Type Max. Length Connectors
Ethernet (1) Cat 5 100 m (330 ft) RJ45 male
Radio Signal (1) RG-6 quad shield coaxial 50 m (165 ft) Male F type
RG-6 with copper center
conductor, quad shield
100 m (330 ft) Male F type
Radio Control (1) Shielded Cat 5,
Outdoor-rated
50 m (165 ft) RJ45 male
Shielded Cat 5E,
Outdoor-rated
100 m (330 ft) RJ45 male