- Apex Generator User Manual
5708009-C 4-75
Apex 1 to 5.5 kW Generator
.
Note: For information on LED flash rates, refer to section 8.2.8 of the DeviceNet 
Specification (revision 2.0).
Note: For information about Module Status LED indications during power-up, refer to 
Section 8.2.4 of the DeviceNet Specification (revision 2.0).
Devicenet Network Status LED
The NET bi-color (amber/green) LED indicates the status of the communication link. 
The following table shows the LED’s various states and their meanings.
Table 4-14. MOD Status LED
LED State Meaning
Off No power the unit is not receiving 
power.
Green (steady) Operational the unit is operating 
normally.
Flashing Green Standby the unit needs maintenance 
because the configuration is 
missing, incomplete, or 
incorrect.
Amber Unrecoverable Fault the unit has experienced a 
fault from which it cannot 
recover; you may need to 
replace the unit.
Flashing Amber/Green Device Self-Testing the unit is running self 
diagnostics
Table 4-15. Network Status LED
LED State Meaning
Off No power The unit is not on-line 
because: 
• it has not completed the 
Dup_MAC_ID test yet
• it is not receiving 
power (check the MOD 
LED).
Green (steady) Link okay The unit is on-line and 
allocated to the master