- Apex Generator User Manual
3-10 5708009-C
Advanced Energy
®
COOLING SPECIFICATIONS
Table 3-5 describes the cooling specifications for the Apex generator.
CEX In • Required signal amplitude range of +2 dBm to +10 
dBm
• Generator operating frequency 
±0.005%
• Input impedance of 50 
Ω, less than 1.5:1 VSWR
CEX Out • Output signal amplitude range of +3 dBm to +7 
dBm
• Generator operating frequency 
±0.005%
• Output impedance of 50 
Ω, less than 1.5:1 VSWR
Table 3-4. Other Electrical Specifications (Continued)
Description PIN Option and Specification
Do not use de-ionized water for cooling purposes. De-ionized water 
causes both corrosion and erosion of cooling manifolds.
Table 3-5. Cooling Specification 
Description Specification
Temperature +35
°C (+95°F) 
Note: Maximum water temperature at minimum flow rate 
and maximum ambient air temperature (+40
° C).
Flow rate
Note: Varies according to the 
option defined by PIN 
position 2.
For 
≤ 3kW 7.6 1pm (2 gpm)
For > 3kW 11.4 1pm (3 gpm)
Pressure
Minimum pressure 
differential (supply to 
drain) required to 
achieve specified 
minimum flow rates)
For 
≤ 3kW 0.9 Bar (13psi)
For > 3kW 2 Bar (29 psi)