- Apex Generator User Manual
4-46 5708009-C
Advanced Energy
®
8
setpoint
Specifies the output setpoint level for 
whatever method of output regulation has 
been selected. Accepts a value of 0 to 8000 
W (for the 8 kW option) or 0 to 10000 W (for 
the 10 kW option) when forward or load 
power regulation is selected. Regular units 
report in units of watts. HALO units report in 
units of tenths of watts.
2 data bytes
16-bit value
1
9
max ext 
feedback
Specifies the external feedback value that 
corresponds to 10 V on the User port; 
requires data bytes arranged as follows:
• First/second byte = a 16-bit value in the 
range of 500 to 5000.
• Third byte = the number of decimal 
places (0 to 4) used to display the 
external feedback signal on the operator 
panel.
3 data bytes
16-bit value
8-bit value
11
select 
active 
target
Specifies which target is active; accepts a 
value of 1 to 4. (Readback command is 156.)
1 data byte
8-bit value
1
12
set target 
life
Sets the life (in kWh) of the target you 
specify. Requires five data bytes arranged as 
follows:
• First byte = the target number
• Second, third, fourth, fifth bytes = target 
life in kWh
Note: A decimal is implied—to get 1 kWh, 
send a value of 100.
(Readback command is 157.)
5 data bytes
8-bit value
32-bit value
1
14
control 
transfer
Sets the active control mode of the generator; 
possible choices are: 2 = host, 4 = User port 
(analog).
1 data byte
8-bit value
1
15
out-of-
setpoint 
timer
Specifies how long the generator can produce 
output that is not equal to the programmed 
setpoint level. Accepts a value of 0 to 599 s. 
(Readback command is 184.)
2 data bytes
16-bit value
1
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)