Applica! on Type 2: Volume of cylindrical tank with or without hemi-
spherical bo" om (measurement result in register 30303-30304)
Register Func! on Value Range
40402 Applica! on Type 2
40403 Volume Units 1 to 7
40404 Decimal Place 0 to 3
40405 Max Distance # Empty Distance
40406 Full Distance Typically = Blanking Distance
40407 Empty Distance 0 to 10364 mm
40436-40437 Tank Diameter 0 to 100,000 mm
40438-40439 Bo" om Radius 0 to 100,000 mm
NOTE: for fl at bo" om tanks, set the Bo" om Radius to 0.
Diameter
Empty
Distance
ŽƩŽŵ
Radius
Full
Distance
or