Specifications

(2) Voltage Range
The APL-10, -12, and -SB are manufactured for nominal line voltages of either
120V AC or 230V AC.
NOTE:The 120V AC model is suitable for use at 100V AC with only a small
reduction in power capability.
Before applying power, carefully check the Line
Voltage Label on the rear
panel located by the AC Mains Power Input connector to insure compatibil-
ity with the local AC mains supply. If your conditions of use change, the APL-
10, -12, and -SB can be modified for alternate line voltage by a qualified serv-
ice technician.You will need to contact your Apogee dealer or distributor and
request a powered subwoofer line voltage adapter kit for each powered sub-
woofer that you wish to change.These kits are available in two versions: to
adapt a unit manufactured for 120V AC to 230V AC, or, to adapt a unit man-
ufactured for 230V AC to 120V AC.
The 120V AC version will function safely within a range of 90V to 132V.
The 230V AC version will function safely within a range of 200V to 253V.
Voltages above the rated maximum should be avoided at all times or damage
may occur!
10
Figure 3
All AC power plugs must always be of the 3-pole grounding type.
Interior of PowerCon connector showing the wiring terminal
DO NOT DEFEAT THE GROUND CONNECTION BY USING
AN AC GROUND LIFT ADAPTER, OR BY CUTTING THE
GROUND PIN OF THE AC POWER PLUG.
Hot
Neutral
Ground