User Guide

MAINTENANCE INSTRUCTIONS
CONBRACO INDUSTRIES, INC. PAGELAND,S.C. Made in U.S.A. I-4222-00
ALL STANDARD VALVES ARE FACTORY SET AT 50 PSI. IN O
RDER TO RAISE OR LOWER THE PRESSURE SETTING, LOOSEN LOCK NUT AND TURN
ADJUSTMENT SCREW CLOCKWISE TO RAISE PRESSURE OR COUNTERCLOCKWISE TO LOWER PRESURE, RETIGHTEN LOCK NUT.
R
INSTALLATION INSTRUCTIONS
THE APOLLO MODEL PR (PRESSURE REDUCING VALVE) IS TO BE INSTALLED IN THE WATER LINE WITH THE ARROW ON THE
VALVE POINTING IN THE DIRECTION OF THE FLOW. THIS VALVE IS FACTORY SET AT 50 PSI. UNLESS OTHERWISE SPECIFIED BY
CUSTOMER. THE PRIMARY PURPOSE OF A PRESSURE REDUCNG VALVE IS TO REDUCE THE WATER PRESSURE COMING IN FROM
THE CITY MAIN DOWN TO A MORE FUNCTIONAL LINE PRESSURE IN THE HOME. IT WILL ENABLE THE HOUSEHOLD TO USE WATER
AT A CONSTANT PRESSURE, WHATEVER THE DEMAND, EVEN TO A REMOTE OUTLET IN THE HOME. AT 100 PSIG WATER WILL HAVE
MORE PUSH BEHIND IT THAN AT 50 POUNDS PRESSURE, SO LESS WATER WILL BE USED BY LOWERING THE PRESSURE. REDUCED
PRESSURE WILL RESULT IN A SAVINGS TO THE USER ON THEIR WATER CONSUMPTION. THE MODEL PR COMES STANDARD WITH A
THERMAL EXPANSION BY-PASS FEATURE WHICH DISSIPATES THE EXPANDED DOWNSTREAM PRESSURE BACK TO THE SERVICE
MAIN. THE APOLLO WATER PRESSURE REDUCING VALVE HAS A UNIQUE CARTRIDGE ASSEMBLY FACILITATING EASY REMOVAL
AND/OR REPLACEMENT USING ORDINARY HAND TOOLS.
WARNING!
THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS
OR OTHER REPRODUCTIVE HARM. (CALIFORNIA LAW REQUIRES THAT THIS WARNING BE GIVEN TO THE CUSTOMERS IN THE
STATE OF CALIFORNIA.). FOR MORE INFORMATION VISIT WWW.APOLLOVALVES.COM.
REPAI R KI T S FOR 3 6 SERI ES PRESSURE REDUCI NG V AL V ES
APOLLO SERIES SIZE CARTRIDGE ASSEMBLY DIAPHRAGM
36-103, 36-203, 36-303 1/2 W6462-06 D2419-00
36-104, 36-204,36-304 3/4 W6462-06 D2419-00
36-105, 36-205, 36-305 1 W6474-06 D4842-00
36-106, 36-206, 36-306 1 1/4 W6712-06 D2558-00
36-107, 36-207,36-307 1 1/2 W6712-06 D2558-00
36-108, 36-208, 36-308 2 W6714-06 D2559-00
TO REPLACE CARTRIDGE
1. SHUT OFF WATER SERVICE TO DWELLING AT MAIN.
2. OPEN A FAUCET TO RELIEVE PRESSURE, LEAVE OPEN.
3. BACK OFF LOCK NUT AND ADJUSTING SCREW.
4. LOOSEN BELL HOUSING, REMOVE SPRING, DISC, AND FRICTION WASHER.
5. REMOVE BOLT, PRESSURE PLATE, AND DIAPHRAGM.
6. REMOVE CARTRIDGE ASSEMBLY.
7. REMOVE SCREEN, CLEAN OFF ANY GRIT, EXAMINE BODY FOR DEBRIS AND FLUSH OUT.
T
O RE-ASSEMBLE
1. SCREW IN NEW CARTRIDGE ASSEMBLY AND TIGHTEN.
2. REPLACE DIAPHRAGM, PRESSURE PLATE AND BOLT.
3. REPLACE SPRING, DISC, FRICTION WASHER, AND BELL HOUSING, TIGHTEN.
4. TURN IN ADJUSTING SCREW TO OLD SETTING, TIGHTEN LOCK NUT.
5. CHECK ALL FITTINGS AND TURN WATER BACK ON.
6. LET WATER RUN A FEW MOMENTS TO FLUSH THE SYSTEM OF AIR.
7. TO ADJUST PRESSURE ON REGULATOR TO DESIRED SETTING, TURN CLOCKWISE TO
RAISE PRESSURE OR COUNTERCLOCKWISE TO LOWER PRESSURE.