Specification
SUBMITTAL SHEET
PEX
Manifolds
PEX
Apollo
®
PEX Manifolds are designed for potable water systems with the use of
PEX pipe to control the ow of water to all xtures.
All Apollo
®
PEX Manifolds comply with the U.S. Safe Water Drinking Act (SDWA)
and the 2011 U.S. Reduction of Lead in Drinking Water Act by containing equal
to or less than 0.25% lead.
The inlets to the manifold are 1" MPT. The outlets on each side of the manifold
are 3/4" MPT. The two inlet adapters that come with the manifold are 3/4"
NPMT x 3/4" PEX. The shuto valves that come with each manifold are 3/4" FPT
w/ Swivel x 1/2" PEX. Apollo
®
PEX Manifolds can be used with Apollo
®
brand
PEX-A or PEX-B pipe.
Specications:
Use Apollo
®
PEX Manifolds with Apollo
®
PEX-A or PEX-B pipe and fasten using Apollo
®
Crimp
Rings, Apollo
®
Pinch Clamps, or Apollo
®
Crimp Sleeves with Apollo
®
PEX Tools. Follow all
instructions included with Apollo
®
tools, fittings, and fasteners.
Approvals:
• ASTM F877
• NSF/ANSI 14 and 61
Pressure & Temperature:
• 160 psi @ 73° F, 100 psi @ 180° F
Installation:
1. Count the number of cold and hot water locations in the house. Be sure to include outside hose bibs and the refrigerator ice maker.
2. Make sure the manifold has as many ports as the house has hot and cold locations.
3. Find an accessible location near the water heater, but not closer than 18” from the water heater outlet, to place the manifold.
4. Attach the shut o valves.
5. Position the manifold in the desired location and nail or screw the mounting bracket to the studs. Make sure all valve handles have room for operation.
6. Attach 1/2” PEX pipe to the inlets and outlets and crimp or clamp securely. Close and cap all unused manifold ports.
7. Label each connection to the water location it supplies. Labels are included with each Apollo manifold.
Job Name:
Job Location:
Engineer:
Contractor:
Tag:
PO Number:
Representative: