Instructions / Assembly

INSTRUCTION SHEET
PEX
Manifold Systems
PEX
1. Count the number of cold and hot water locations in the house. Be sure to include outside hose bibs and the refrigerator ice maker.
2. Make sure the manifold has as many ports as the house has hot and cold locations.
3. Find an accessible location near the water heater, but not closer than 18" from the water heater outlet, to place the manifold.
4. Attach the shut o valves. To create a 3/4" PEX pipe inlet, attach the included adapters. For a 1" MPT pipe inlet, leave the inlet as is.
5. Position the manifold in the desired location and nail or screw the mounting bracket to the studs. Make sure all valve handles have room for
operation.
6. Attach pipe to inlets. Attach 1/2" PEX pipe to the outlets and crimp or clamp securely. Close and cap all unused manifold ports.
7. Label each connection to the water location it supplies. Labels are included with each Apollo manifold.