Specification

ss-69ELF-PRVWG_07/06/21
VALVES
The Mosack Group, Inc.
Mint Hill, NC 28227
1.888.229.2874
www.apolloow.com
ss-69ELF-PRV_01/20/21
PEX
Flow Capacity:
MODEL PRE FLOW CHART
Note: Flow curves are based on static conditions of 100psi inlet pressure and
50 psi outlet pressure. Pressure differential is the difference between the
supply pressure and adjusted outlet pressure measured in the static (closed)
condition. Pressure fall-off is the decrease in downstream regulated pressure
as the flow increases.
The Mosack Group, Inc.
Mint Hill, NC 28227
1.888.229.2874
www.apolloow.com
CPVC FNPT
PEX B
PEX A PRESS PUSH
PEX-A Installation:
1. Cut pipe squarely and place expansion sleeve on end.
2. Insert expansion tool head into tubing and expand.
3. Immediately remove tool and insert valve end into pipe to
shoulder. Pipe may take up to two minutes to fully seal.
PEX-B Installation:
1. Cut pipe squarely and remove any burrs.
2. Slide ring, clamp or sleeve over end of pipe.
3. Insert valve barb end into pipe.
4. Fasten according to tool directions.
Push Installation:
1. Cut pipe squarely and remove any burrs.
2. Mark insertion depth using depth gauge (sold separately).
3. Push and twist pipe into valve until valve end edge meets
depth line.