Owner`s manual

18
your baery as soon as possible. If you have been using your light on the
surface, it is possible it has over heated and engaged the temperature
protecon circuit. Allow your light to cool before aempng to turn it on
again.
Halcyon Primary Light General Troubleshooting
What to do if your light does not work
1. Verify that the baery is properly connected, that all wire connecons are
secure, and that the baery is not completely drained. Use a volt meter to
verify that the baery has at least some voltage. The baery should read
at least 12.5 volts. If you believe that your power pack has failed, test the
quesonable light head with a dierent baery.
For HID Lighng:
2. Verify that the HID bulb is not damaged. If the bulb needs to be changed,
please refer to the manual secon on changing the bulb. Remember to be
careful removing the lamp cover and to avoid touching the bulb with your
bare hands.
3. Verify that the HID bulb is seated properly in the socket. Occasionally the
HID bulb connecon can be compromised if the light head is suciently
bumped or jarred during transport. To check the HID bulb seang, the
lamp cover must be removed. For a comprehensive discussion of this pro-
cess please see the manual secon on changing a bulb. In general, be sure
that the HID bulb is not touched directly and that you are careful removing
the lamp cover.
4. If you suspect the switch may be the problem, please contact Tech Ser-
vices for assistance.
What to do with an HID light that works sporadically
If your HID light ickers or only works sporadically, it is very likely to be the
result of a poor connecon. It is possible that this weak connecon is at
the bulb and socket, or that wires leading to the baery are frayed. Please
consult the troubleshoong secon entled "What to do if your light does
not work" for more detail on correcng these problems.
A sporadic HID light is more likely the result of a poor connecon in the cord.
Test for a poor connecon or a kink in the cord by working the cord back
and forth, starng by the light head and working back toward the canister,
to see if the sporadic problem can be iniated. A kink in the cord is likely to
eventually break the wire connecons within the cord.