HALCYON HMI VIDEO LIGHT INSTRUCTIONS
Follow Halcyon's general lighng informaon for care, charging and mainte-
nance of the HMI video lighng system.
SETUP: Assemble the HMI by placing the ballast housing on top of the baery
canister while aligning the banana plugs with the baery terminals. Ensure
that the baery canister O-ring is in place before locking the latches. Plug the
cord into the lid and screw down the locking retainers. Plug the other end of
the cord into the light head and screw down the locking retainers.
CHARGING: Set the voltage selector switch
on the back of the charger to the appro-
priate voltage. Plug the charger in to a
wall socket and turn the charger on. Plug
the charging plug into the baery. A fully
discharged baery will take approximately
3 hours to charge. A fully charged baery
will provide 1 hour of burn me on a single
200-wa. Use of HMI in extremely cold
condions will impact the run me.
Please note that the Halcyon HMI video
light is a 24-volt system. Always use the
supplied 24-volt charger to charge the baery.
Use of an inverter is not recommended.
TROUBLESHOOTING the HMI
Light will not strike
• Ensure that the battery is connected
• Ensure that the cord is securely connected at both ends
• Ensure that the bulb is properly seated
Light performs intermittently
• Ensure that the cord is securely connected at both ends
• Ensure that the bulb is properly seated
• Ensure that the battery is fully charged
The light does not burn for the specied time
• Ensure that the battery is fully charged
• Ensure that the cord is securely connected at both ends
• Ensure that the bulb is properly seated