User`s manual

Table Of Contents
6. Viewer
166/402
_________________________________________________
Barco – Apollo – DOC-3197-2 – user's manual – Revision 08 – November 2006
6.14 Global Viewer Parameters
The following table lists the parameters that apply to all viewers.
A parameter can be activated or deactivated (values 1 or 0) or have a value specified with the list position of the
corresponding entry in the ServerData\Globals.ini file.
Exception: The position of the In Display Caption is not defined in the ServerData\Globals.ini
file. The following assignments apply to the positions:
1 Northeast
2 Northwest
3 Southeast
4 Southwest
5 Center
6 North Center
7 South Center
The viewers can be controlled by the viewer command interface, cf. Viewer command Interface.
Parameter Values Description
? Writes the help command line parameter into the log file
splash [1|2500]
Disables (1) or enables splash screen when starting viewer (2500:
time in ms the splash screem is displayed)
Ident [] Unambiguous name of the viewer instance
IdcEnabled [0|1] Deactivates/activates blanking
IdcPosition [1..7] Position of the displayed text in blanking mode; the value is con-
verted based on the assignment listed above.
IdcText [] Text in blanking mode
IdcTextColor [1..]
Text color; value matches the list position in definition file Server-
Data\Globals.ini.
IdcBackColor [1..]
Background color; value matches the list position in definition file
ServerData\Globals.ini.
IdcOpaque [0|1]
Activates or deactivates background color. Zero: the background is
transparent. One: the color defined as IdcBackColor is used as the
background color.
IdcOverlap [0|1] 0: IDC is placed outside the insertion, 1: IDC is placed inside the
insertion
IdcTextSize [1..] Text size; value matches the list position in definition file Server-
Data\Globals.ini.
IdcImage [1..] Bitmap used as overlay over the viewer window when blanking