12.8.1.1 DefaultPermission
DefaultPermission is coded as 16 bit hexadecimal. The following table gives an overview about the bits. Please
see the respective item to get information about the assignment.
n.a. n.a. n.a. s7 s6 s5 s4 s3 s2 s1 save per
m
wr_ad wr rd
re-
stricte
d
Bit Meaning Description (example: layout)
Restricted
Restricted Has to be set, otherwise the security provider neglects the respec-
tive object
Rd
Read Layout is visible
Wr
Write Layout can be loaded
Wr_ad
Write advanced Windows of a layout can be moved
Perm
permission Edit permission is available
Save
Save Layouts can be saved
S1 to S7
Special 1 … Special 7 -
n.a.
Not assigned -
To get information about the meaning of a specific bit with respect to a different object
than a layout, please refer to Permissions