5.3.2.3 Projection module OverView PU
Custom Properties Type of Module OverView-cPU67-DL (should not be changed)
Data Connection Point
(blue):
VGA_Digital_Input
Possible to connect with VGA_Digital_Output
of the digital graphic card
Control Connection Point
(red):
Serial_Input
Possible to connect with Serial_Output of previous
device or the control computer
Serial_Output Possible to connect with Serial_Input of subsequent
device
5.3.2.4 Projection module OverView-mP
Custom Properties Type of Module OverView-mP (should not be changed)
Data Connection Point
(blue):
VGA_Digital_Input
Possible to connect with VGA_Digital_Output
of the digital graphic card
the digital output of Hermes D2D
the digital output of Hermes V2A
Control Connection Point
(red):
Serial_Input
Possible to connect with Serial_Output of previous
device or the control computer
Serial_Output Possible to connect with Serial_Input of subsequent
device