User`s manual

Table Of Contents
5. Control Room Configurator
Barco – Apollo – DOC-3197-2 – user's manual – Revision 08 – November 2006
__________________________________________________
47/402
5.3.2.12 Control Computer Argus / TransForm A
Custom Properties Name
Enter the name of the computer in the network. Do
not specify an IP address if the name has been de-
fined.
Reserved COM Ports
Select from the list box the respective number of
reserved COM ports (WindowsNT: 4, Windows2000:
2). The COM ports of the serial I/O card then gets the
subsequent numbers (3 and 4, or 5 and 6 respec-
tively)
IP Address
Enter the IP address if the computer does not have
an assigned name. The name property then remains
undefined!
Number of Viewers
Enter the number of viewers the Apollo project will
include. The required communication memory for
the Apollo Master/Slave/Client will be calculated
accordingly.
Network Connection Point
(green):
LAN
Possible to connect to LAN
Control Connection Point
(red):
Serial_Output Com1
Possible to connect with Serial_Input of a device or
of the Source Command.
Enter the corresponding baud rate.
Serial_Output Com2 Possible to connect with Serial_Input of a device or
of the Source Command.
Enter the corresponding baud rate.
Parallel_Output LPT1
Parallel_Output LPT2
PCI Slots For PCI ExtCard only, to connect with a TransForm A
OmniBus, or with I/O serial/parallel ports
Software Container Apollo Base
Desktop Server
SNMP Manager
SNMP Agent RC
Device Command
OCM
Argus Scan Server
TCP Command